Skip to content

CRW® DHRSL5

by Integra Lifesciences Corp. 2 variants

CRW DHRSL5 is a stereotactic radiosurgical invasive head frame (FDA Class II; FDA product code HAW, Neurological stereotaxic Instrument) made by Integra Lifesciences Corp., cleared under FDA 510(k) K160811 on 6 Dec 2016 (1 earlier submission) and listed in FDA GUDID since 28 Jun 2024 (UDI-DI 10381780542278), active as of 23 Oct 2026. 4 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

4 closed

Documents

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10381780542278 UDI-DI Date28 Jun 2024ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Abbreviated NumberK160811 Date6 Dec 2016DecidedStatusActive

Official records

From the FDA record

Device description
Disposable Head Ring Screws, Long (5 Packs of 2)
MRI safety
MR Conditional
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K160811 decided 6 Dec 2016 Active· +1 more in the status table
  • FDA GUDID UDI-DI 10381780542278 listed 28 Jun 2024 Listed

Recalls

4 recalls · FDA

    • Terminated Z-0025-2016 FDA Class II initiated 21 Aug 2015

    Integra identified that the UCHRAP component (Arc Adapter Plate) would not assemble properly to the UCHRAR component (ARC Adapter Ring) of the Compact Head Ring Adapter due to an error in the manufacturing drawing.

  • 2 recalls, same reason

    • Terminated Z-2428-2012 FDA Class II initiated 9 Aug 2012
    • Terminated Z-2429-2012 FDA Class II initiated 9 Aug 2012

    T-handle screw is used on a complementary product to the CRW, the Integra HRAIM, which is the CT-compatible intubation Head Ring Assembly. When the T-handle on the HRAIM intubation hoop is tightened, the T-handle could stop in a vertical position that prevents the CRWPRECISE and certain models of the CRW-ASL from seating properly on the head ring although it appears to be fully seated

    • Terminated Z-1400-2011 FDA Unclassified (pre-2012) initiated 12 Jan 2011

    Overall length of the intubation hoop in the HRAIM Intubation Head Ring Assembly is too long and will not allow a device to to attach

Timeline

7 dated events

  1. Cleared FDA 510(k) K944463
  2. Recall initiated FDA recalls Z-1400-2011
  3. Recall initiated FDA recalls Z-2428-2012
  4. Recall initiated FDA recalls Z-2429-2012
  5. Recall initiated FDA recalls Z-0025-2016
  6. Cleared FDA 510(k) K160811
  7. Listed FDA GUDID 10381780542278

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Crw®
Generic name
Stereotactic radiosurgical invasive head frame
Model / Ref / Catalog
DHRSL5
Primary DI / UDI-DI
10381780542278
510(k) Number
FDA product code
HAW
GMDN term
Stereotactic radiosurgical invasive head frame
Device class
Class II
Regulation number
882.4560
GUDID distribution status
In Commercial Distribution
MRI safety
MR Conditional

Similar devices

Other devices filed under FDA product code HAW (Neurological stereotaxic Instrument).

Other devices from Integra Lifesciences Corp.

See all devices from Integra Lifesciences Corp. →

Properties

  • Supplied sterile
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (9, all answered No)