Identity
- Trade Name
- D-Stat® Flowable Hemostat FDA UDI
- Generic Name
- Collagen haemostatic agent, non-antimicrobial FDA UDI
- Device Name
- Each Vascular Solutions D-Stat® flowable hemostat (D-Stat) includes the following components: Thrombin vial (5,000 units); Collagen (200mg), contained in 10ml syringe with attached mixing luer; Diluent vial (5ml); Mixing accessories (10ml syringe and needleless, non-coring vial access device); Applicator tips: (1) small bore tip, (1) 20-Gauge, 2.75" needle. The thrombin is a protein substance produced through a conversion reaction in which prothrombin of bovine origin is activated by tissue thromboplastin of bovine-origin in the presence of calcium chloride. It is supplied as a sterile powder that has been freeze-dried in the final container. Also contained in the thrombin vial are mannitol and sodium chloride. Mannitol is included to make the dried product friable and more readily soluble. The material contains no preservative and has been chromatographically purified. Thrombin requires no intermediate physiological agent for its reaction. It converts fibrinogen directly to fibrin. The collagen is a soft, white, pliable, absorbent hemostatic agent derived from purified bovine deep flexor tendon. It is prepared in a loose fibrous form. Collagen attracts platelets that adhere to the fibrils and undergo the release phenomenon to trigger aggregation of platelets into thrombi in the interstices of the fibrous mass. The collagen provides a three-dimensional matrix for additional strengthening of the clot. The effect on platelet adhesion and aggregation is not inhibited by heparin in vitro. The diluent is a sterile solution of calcium chloride and water, buffered with tromethamine (TRIS). Using the mixing accessories, both the thrombin and collagen are reconstituted with the diluent prior to use. The hemostat is delivered to the intended treatment site using the provided applicator tips. Hemostasis is achieved by the physiological coagulation-inducing properties of the D-Stat. The D-Stat is biocompatible, non-pyrogenic, and intended to be left in situ. FDA UDI
- Model / Reference
- 4000 FDA UDI
- Description
- Each Vascular Solutions D-Stat® flowable hemostat (D-Stat) includes the following components: Thrombin vial (5,000 units); Collagen (200mg), contained in 10ml syringe with attached mixing luer; Diluent vial (5ml); Mixing accessories (10ml syringe and needleless, non-coring vial access device); Applicator tips: (1) small bore tip, (1) 20-Gauge, 2.75" needle. The thrombin is a protein substance produced through a conversion reaction in which prothrombin of bovine origin is activated by tissue thromboplastin of bovine-origin in the presence of calcium chloride. It is supplied as a sterile powder that has been freeze-dried in the final container. Also contained in the thrombin vial are mannitol and sodium chloride. Mannitol is included to make the dried product friable and more readily soluble. The material contains no preservative and has been chromatographically purified. Thrombin requires no intermediate physiological agent for its reaction. It converts fibrinogen directly to fibrin. The collagen is a soft, white, pliable, absorbent hemostatic agent derived from purified bovine deep flexor tendon. It is prepared in a loose fibrous form. Collagen attracts platelets that adhere to the fibrils and undergo the release phenomenon to trigger aggregation of platelets into thrombi in the interstices of the fibrous mass. The collagen provides a three-dimensional matrix for additional strengthening of the clot. The effect on platelet adhesion and aggregation is not inhibited by heparin in vitro. The diluent is a sterile solution of calcium chloride and water, buffered with tromethamine (TRIS). Using the mixing accessories, both the thrombin and collagen are reconstituted with the diluent prior to use. The hemostat is delivered to the intended treatment site using the provided applicator tips. Hemostasis is achieved by the physiological coagulation-inducing properties of the D-Stat. The D-Stat is biocompatible, non-pyrogenic, and intended to be left in situ. FDA UDI
Identifiers
- Primary DI / UDI-DI
- M20640000 FDA UDI
- FDA Product Code
- FRO FDA UDI
- GMDN Term
- Collagen haemostatic agent, non-antimicrobial FDA UDI
Classification
- Device Class
- U FDA UDI
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
Yes
FDA UDI
Single Use
Yes
FDA UDI
Implantable
Yes
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
Yes
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
Yes
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
Yes
FDA UDI
Serial Number
No
FDA UDI
Expiration Date
Yes
FDA UDI
Manufacturing Date
No
FDA UDI
Category: Collagen haemostatic agent, non-antimicrobial
D-Stat® Flowable Hemostat by Vascular Solutions, Inc. — Class U — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Similar devices
Also classified as Collagen haemostatic agent, non-antimicrobial.
- Floseal — Baxter Healthcare Corp · Class III
- Floseal Hemostatic Matrix — Baxter Healthcare Corp · Class III
- Avitene — Davol Inc. · Class III
- Helistat® ABSORBABLE COLLAGEN HEMOSTATIC SPONGE — Integra Lifesciences Corp. · Class III
- FLOSEAL HEMOSTATIC MATRIX — Baxter Healthcare Corp · Class III
- Floseal Special Applicator Tips — Baxter Healthcare Corp · Class III
- Simpurity — SAFE N SIMPLE LLC · Class I
- D-STAT — TELEFLEX INCORPORATED · Class III
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class U | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Vascular Solutions, Inc.
Sources (1)
- FDA UDI a29d4773-e315-41a7-8436-1b903fb53977 35 fields · synced May 30, 2026