D630 Upgrade H2401JF
by GE Medical Systems Israel, Functional Imaging
D630 Upgrade H2401JF is a stationary gamma camera system (FDA Class II; FDA product code KPS, System, tomography, computed, emission) made by GE Medical Systems Israel, Functional Imaging, cleared under FDA 510(k) K111445 on 3 Jun 2011 and listed in FDA GUDID since 11 Jul 2017 (UDI-DI 00840682123761), active as of 23 Oct 2026. 9 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
2 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00840682123761 | Date11 Jul 2017 | StatusListed |
| United States | FDA 510(k)SESE | NumberK111445 | Date3 Jun 2011 | StatusActive |
Official records
- AccessGUDID record 00840682123761
- FDA 510(k) database K111445
From the FDA record
- Device description
- B615 to D630 upgrade kits option
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K111445 decided 3 Jun 2011 Active
- FDA GUDID UDI-DI 00840682123761 listed 11 Jul 2017 Listed
Recalls
-
- Ongoing Z-0890-2025
GE HealthCare has become aware that certain Infinia, VariCam/VG/VH, Brivo NM 615, Discovery NM 630, Discovery NM/CT 670, and Optima NM/CT 640 Nuclear Medicine systems (see Affected Products Details and Appendices) could have been transported or relocated without proper detector support, which can result in excessive load being applied to the detector mounting mechanisms. If this occurs, it can potentially result in a detector fall and lead to life-threatening bodily injury.
-
- Ongoing Z-1054-2023
A mitigation may not be correctly implemented. If this is the case, the detector can fall, leading to life-threatening bodily injury.
-
- Terminated Z-0856-2021
GE Healthcare has become aware that rotor bearing screws were found loose on one detector in the field, leading to the release of one of the four rotor bearings in the detector.
-
- Terminated Z-2994-2020
- Terminated Z-2995-2020
Rotor bearing screws were found loose on detector.
-
- Terminated Z-1257-2019
During installation of certain Nuclear Medicine systems delivered with dismounted detectors, some detector screws may not have been secured correctly, leading to the possible loss of one detector mounting design redundancy.
-
- Terminated Z-0367-2014
GE Healthcare has recently become aware of a potential safety issue related to a SPECT scan procedure used for pulmonary imaging. Contact between the Detector (GE Healthcare Discovery NM/CT 670, and/or Optima NM/CT 640, and/or Discovery NM630, and/or Brivo NM 615 all configurations) and the Patient's elbow may occur during SPECT protocols using 450 angular steps in scenarios when a Patients a
-
- Terminated Z-1791-2013
GE became aware of an incident at a VA Medical Center facility in the US in which a patient died due to injuries sustained while being scanned on an Infinia Hawkeye 4 Nuclear Medicine System. UPDATE: On July 03, 2013 GE notified hospitals that they are recalling several Nuclear Medicine Imaging Systems because serious injuries or deaths could occur due to the failure mode associated with this re
-
- Terminated Z-0121-2013
GE Healthcare has recently become aware of a potential safety issue associated with the table pallet of your Discovery NM/CT 670 and/or Discovery NM630 system which may impact operation safety. At scan setup, during gantry rotation towards scanning position, a potential contact between the table-pallet-edge and the detector was identified. Such occurrence may damage the pallet front-edge and
-
- Terminated Z-1111-2012
GE Healthcare has recently become aware of a potential safety issue associated with the collimator cart and lead cover of your Discovery NM/CT 670 and/or Discovery NM 630 system that may impact operator safety. 1. The cart locking pin release and cart disengagement could result in the collimator falling down and could lead to operator or service personnel injury. 2. Another issue is that the
Timeline
- Recall initiated FDA recalls Z-0121-2013
- Recall initiated FDA recalls Z-1791-2013
- Recall initiated FDA recalls Z-0367-2014
- Listed FDA GUDID 00840682123761
- Recall initiated FDA recalls Z-1257-2019
- Recall initiated FDA recalls Z-2994-2020
- Recall initiated FDA recalls Z-2995-2020
- Recall initiated FDA recalls Z-0856-2021
- Recall initiated FDA recalls Z-1054-2023
- Recall initiated FDA recalls Z-0890-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- D630 Upgrade
- Generic name
- Stationary gamma camera system
- Model / reference
- H2401JF
- Primary DI / UDI-DI
- 00840682123761
- 510(k) Number
- FDA product code
- KPS
- GMDN term
- Stationary gamma camera system
- Device class
- Class II
- Regulation number
- 892.1200
- GUDID distribution status
- In Commercial Distribution
Other devices from GE Medical Systems Israel, Functional Imaging
See all devices from GE Medical Systems Israel, Functional Imaging →