Djo Surgical 508-01-032
Djo Surgical 508-01-032 is a device of GMDN type total reverse shoulder prosthesis (FDA Class II; FDA product code PHX, shoulder prosthesis, reverse configuration) made by Encore Medical LP, cleared under FDA 510(k) K051075 on 27 May 2005 and listed in FDA GUDID since 7 Aug 2017 (UDI-DI 00888912024693), active as of 8 Nov 2026. 4 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
3 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00888912024693 | Date7 Aug 2017 | StatusListed |
| United States | FDA 510(k)SESE | NumberK051075 | Date27 May 2005 | StatusActive |
Official records
- AccessGUDID record 00888912024693
- FDA 510(k) database K051075
From the FDA record
- Device description
- SOCKET, INSERT 32MM SEMI RSP HUMERAL
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K051075 decided 27 May 2005 Active
- FDA GUDID UDI-DI 00888912024693 listed 7 Aug 2017 Listed
Recalls
-
- Ongoing Z-1460-2026
Knee and Humeral socket implants contain incorrect labeling.
-
- Ongoing Z-0282-2024
Two different humeral socket Insert devices were swapped during packaging, which could result in surgeons not having the correct device for surgery, which could cause a delay in surgery.
-
- Ongoing Z-2606-2023
Orthopedic device components were not subjected to final sterilization before shipment, which if implanted may lead to varying degrees of infection, which may require treatment, prolonged monitoring, and may lead to revision surgery
-
- Completed Z-0625-2024
Mislabeling
-
- Terminated Z-2739-2011
The device has the potential to not appropriately mate with the humeral stem.
Timeline
- Cleared FDA 510(k) K051075
- Recall initiated FDA recalls Z-2739-2011
- Listed FDA GUDID 00888912024693
- Recall initiated FDA recalls Z-2606-2023
- Recall initiated FDA recalls Z-0282-2024
- Recall initiated FDA recalls Z-0625-2024
- Recall initiated FDA recalls Z-1460-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Djo Surgical
- Generic name
- Total reverse shoulder prosthesis
- Model / reference
- 508-01-032
- Primary DI / UDI-DI
- 00888912024693
- 510(k) Number
- FDA product code
- PHX
- GMDN term
- Total reverse shoulder prosthesis
- Device class
- Class II
- Regulation number
- 888.3660
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code PHX (shoulder prosthesis, reverse configuration).
- Comprehensive® Convertible Glenoid - Vivacit-E Liner by Biomet Manufacturing Corp
- Bio-Modular® Choice Instruments 406668 by Biomet Orthopedics, Inc.
- Identity™ SBHS3125 by Zimmer, Inc.
- INHANCETM Reverse Glenoid Peripheral Posts by DePuy Ireland UC
- Humeral Cup Stability 314-0903 by FX SOLUTIONS
- INHANCE™ Reverse Shoulder System by DePuy Ireland UC
- Humelock II Cemented Reversible Shoulder 109-4556 by FX SOLUTIONS
- Arthrex Univers Revers Modular Glenoid System by Arthrex, Inc.
- ARROW Reverse Shoulder long keel and short keel glenoid base by FOURNITURES HOSPITALIERES INDUSTRIE
- Anatomical Shoulder™ Domelock® 01.04212.565 by Zimmer, Inc.