Skip to content

Equinoxe SPI-041516

by Exactech, Inc.

Equinoxe SPI-041516 is a joint prosthesis implantation kit (FDA Class II; FDA product code KWT, Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented) made by Exactech, Inc., cleared under FDA 510(k) K180632 on 25 Jul 2018 and listed in FDA GUDID since 27 Oct 2021 (UDI-DI 10885862606808), active as of 23 Oct 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

3 ongoing

This device is named in the recall

Documents

510(k) K180632

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10885862606808 UDI-DI Date27 Oct 2021ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK180632 Date25 Jul 2018DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K180632 decided 25 Jul 2018 Active
  • FDA GUDID UDI-DI 10885862606808 listed 27 Oct 2021 Listed

Recalls

3 recalls · 3 ongoing · FDA

  • 2 recalls, same reason

    • Ongoing Z-1420-2024 FDA Class II initiated 6 Mar 2024 on shared 510(k) K180632
    • Ongoing Z-1421-2024 FDA Class II initiated 6 Mar 2024 on shared 510(k) K180632

    The packaging of these affected UHMWPE humeral liners and glenoids are nonconforming as they do not meet the established packaging specification. They were packaged in vacuum bags that did not contain an additional oxygen barrier layer consisting of Ethylene Vinyl Alcohol (EVOH).

    • Ongoing Z-0579-2024 FDA Class II initiated 21 Nov 2023

    Exactech has received 3 complaints for 4 devices related to a loss of vacuum in the inner-most vacuum bag.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

5 dated events

  1. Cleared FDA 510(k) K180632
  2. Listed FDA GUDID 10885862606808
  3. Recall initiated FDA recalls Z-0579-2024
  4. Recall initiated FDA recalls Z-1420-2024
  5. Recall initiated FDA recalls Z-1421-2024

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Equinoxe
Generic name
Joint prosthesis implantation kit, reusable
Model / Ref / Catalog
SPI-041516
Primary DI / UDI-DI
10885862606808
510(k) Number
FDA product code
KWT
GMDN term
Joint prosthesis implantation kit, reusable
Device class
Class II
Regulation number
888.3650
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Similar devices in this category

Other devices filed under Joint prosthesis implantation kit, reusable.

Other devices from Exactech, Inc.

See all devices from Exactech, Inc. →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
Other properties (12, all answered No)