Skip to content

Estrone RIA

by IMMUNOTECH s.r.o.

Ref DSL8700Model Immunoassay DSL8700

Estrone RIA (DSL8700) is an in vitro diagnostic device (EU IVDR Class B; FDA Class I; FDA product code CGF, Radioimmunoassay, Estrone) made by IMMUNOTECH s.r.o., registered in EUDAMED on 7 Dec 2022 (Basic UDI-DI 150995905DSL8700GE), cleared under FDA 510(k) K935013 on 16 Jun 1994 and listed in FDA GUDID since 6 Jul 2023 (UDI-DI 15099590211615), active as of 22 Oct 2026. 4 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE IVDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

3 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K935013

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing GUDID Number15099590211615 UDI-DI Date6 Jul 2023ListedStatusListed GUDID: in commercial distribution
European UnionCE/IVDR EUDAMED Number150995905DSL8700GE Basic UDI-DI 15099590211615UDI-DIDate7 Dec 2022RegisteredStatusActive
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK935013 Date16 Jun 1994DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 150995905DSL8700GE registered 7 Dec 2022 Active
  • FDA 510(k) K935013 decided 16 Jun 1994 Active
  • FDA GUDID UDI-DI 15099590211615 listed 6 Jul 2023 Listed

Recalls

4 recalls · 3 ongoing · FDA

    • Ongoing Z-1369-2026 FDA Class II initiated 15 Dec 2025 UDI-DI 15099590211615 listed

    The affected Estrone RIA kit lots may rarely give falsely high patient results which might cause Temporary injury of Remote probability. Only in some (very rare) cases may the issue occur.

    • Ongoing Z-2152-2025 FDA Class II initiated 12 Jun 2025 UDI-DI 15099590211615 listed

    A specific lot of bovine serum albumin (BSA) used for manufacturing of coated tubes (CT) that are included in the Estrone RIA kit lots caused different affinity of manufactured coated tubes to patient samples, causing falsely increased assay results for the impacted Estrone RIA kits.

    • Ongoing Z-2336-2025 FDA Class II initiated 12 Jun 2025 UDI-DI 15099590211615 listed

    Estrone RIA kit lots may rarely give falsely high patient results which might cause Temporary injury of Remote probability or rarely give falsely low patient results which might cause Permanent injury of Remote probability. Only in some (very rare) cases may the issue occur.

    • Terminated Z-1685-2011 FDA Unclassified (pre-2012) initiated 22 Apr 2010

    Beckman Coulter has confirmed that eight Estrone RIA kit (Ref DSL 8700) lots are inaccurately calibrated to the firm's internal reference calibrator. Lots 992637, 100115A, 100205A, 100205RA, and 100226A have now expired and should not be in active use any more.

Timeline

7 dated events

  1. Cleared FDA 510(k) K935013
  2. Recall initiated FDA recalls Z-1685-2011
  3. Registered EUDAMED 150995905DSL8700GE
  4. Listed FDA GUDID 15099590211615
  5. Recall initiated FDA recalls Z-2152-2025
  6. Recall initiated FDA recalls Z-2336-2025
  7. Recall initiated FDA recalls Z-1369-2026

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
Estrone (oestrone) IVD, kit, radioimmunoassay
Model / Ref / Catalog
Immunoassay DSL8700, DSL8700
Primary DI / UDI-DI
15099590211615
Basic UDI-DI
150995905DSL8700GE
510(k) Number
FDA product code
CGF
EMDN code
W0102050204 Estrone
GMDN term
Estrone (oestrone) IVD, kit, radioimmunoassay
Device class
Class B EUDAMED
Class I GUDID
Regulation number
862.1280
EU registration type
Standard device
EU market of registration
Czechia
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class B
GUDID
Class I

Device class is stated on each registry's own scale: Class B in the EU (EUDAMED), Class I in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
CZ-MF-000001761

Similar devices in this category

Other devices filed under PREGNANCY TESTING HORMONES / PROTEINS.

Other devices from IMMUNOTECH s.r.o.

See all devices from IMMUNOTECH s.r.o. →

Properties

  • Reagent
  • IVD kit
  • Professional testing
  • Prescription use
  • Convenience kit
  • Lot / batch number
  • Expiration date
  • Manufacturing date
Other properties (18, all answered No)