Exactamix H938173
Exactamix H938173 is a Class II device made by Baxter Healthcare Corp, cleared under FDA 510(k) K002705 on 28 Mar 2001 and listed in FDA GUDID since 23 Sep 2016 (UDI-DI 00085412475783), active as of 23 Oct 2026. 15 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
8 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00085412475783 | Date23 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK002705 | Date28 Mar 2001 | StatusActive |
Official records
- AccessGUDID record 00085412475783
- FDA 510(k) database K002705
Across registries
- FDA 510(k) K002705 decided 28 Mar 2001 Active
- FDA GUDID UDI-DI 00085412475783 listed 23 Sep 2016 Listed
Recalls
-
- Ongoing Z-2262-2026
Affected lots may contain incorrect 0.8-micron filters. Use of a 0.8-micron filter in place of the validated 3-micron filter may lead to reduced flow efficiency, incomplete or slower transfers of ingredients, or system alarms. This issue may lead to clinical effects such as electrolyte imbalance, metabolic instability, delayed recovery, etc.
-
- Ongoing Z-3084-2024
- Ongoing Z-3082-2024
- Ongoing Z-3083-2024
- Ongoing Z-3085-2024
Baxter Healthcare Corporation has received increased customer reports of particulate matter in the Automated Compounding Device Inlets (disposable inlet), Product Codes H938173, H938174, H938175, H938176, used with the ExactaMix and ExactaMix Pro compounders. Particulate matter has been observed within the inlet primary packaging inlet components, including within the sterile fluid path tubing, before use.
-
- Ongoing Z-1002-2024
- Ongoing Z-1001-2024
An error was identified in software versions 2.0.8 and 2.1.8 while using the "Use Some Overfill" feature which may lead to over-delivery of an ingredient. This issue can result in redundant ingredient delivery of the requested overfill volume.
-
- Ongoing Z-1570-2022
There is a potential for leaking valves on ports 1 to 4 in certain lots of valve sets.
-
- Terminated Z-1908-2018
- Terminated Z-1911-2018
- Terminated Z-1910-2018
- Terminated Z-1909-2018
Specific lots of EXACTAMIX Inlets listed below due to incorrectly performed over-labeling. The inlets were over-labeled with a blank label, or with a label containing an extended expiration date. If the product is used beyond the expiration date,
-
- Terminated Z-1752-2013
Baxter Healthcare is recalling certain ExactaMix automated compounding devices due to the complementary metal oxide semi-conductor battery failure resulting in resetting the internal clock of the device to midnight December 31, 2010.
-
- Terminated Z-1197-2010
Molding defect in the valve body causes leaking.
-
- Terminated Z-0210-04
If device stops due to an alarm or operater pause, inlet valves will remain open, allowing some unwanted mixing of ingredients in the valve chamber..
Timeline
- Recall initiated FDA recalls Z-1910-2018
- Recall initiated FDA recalls Z-1909-2018
- Recall initiated FDA recalls Z-1570-2022
- Recall initiated FDA recalls Z-1002-2024
- Recall initiated FDA recalls Z-1001-2024
- Recall initiated FDA recalls Z-3084-2024
- Recall initiated FDA recalls Z-3082-2024
- Recall initiated FDA recalls Z-3083-2024
- Recall initiated FDA recalls Z-3085-2024
- Recall initiated FDA recalls Z-2262-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Exactamix
- Generic name
- Compounding transfer set
- Model / Ref / Catalog
- H938173
- Primary DI / UDI-DI
- 00085412475783
- 510(k) Number
- FDA product code
- LHI, NEP
- GMDN term
- Compounding transfer set
- Device class
- Class II
- Regulation number
- 880.5440
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code LHI (Set, i.V. Fluid transfer).
- Swabable Vial Adapter 8072022 by West Pharma. Services IL, Ltd.
- Vial Adapter Ø13mm by Avenir Performance Europeenne Medical (Apem)
- EXACTA-MIX 2400 COMPOUNDING SYSTEM, MODEL EXACTA-MIX 2400 by Baxa Corp.
- MEDSOURCE SELECTABLE IV SET by MEDSOURCE INTERNATIONAL LLC
- VIAL2BAG DIRECT CONNECT by Medimop Medical Projects, Ltd.
- DOUBLE LUMEN TRANSFER DEVICE by Codan Trading Co.
- VENTED NEEDLE by Excel Medical, Inc.
- Vialok Single Vial Access Device Vented by Yukon Medical, LLC
- APEX Compounding System Transfer Set by B. Braun Medical, Inc.
- SYRINGE ADAPTOR by Excel Medical, Inc.