Skip to content

EXPert 03.010.004

by Synthes GmbH

EXPert 03.010.004 (03010004) is a bone-nailing compression screw (FDA Class II; FDA product code JDS, Nail, Fixation, Bone) made by Synthes GmbH, cleared under FDA 510(k) K040762 on 12 Apr 2004 and listed in FDA GUDID since 14 Sep 2015 (UDI-DI 10886982066923), active as of 12 Nov 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

2 closed

Documents

510(k) K040762

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 12 Nov 2026.

Regulatory status

as of registry sync 12 Nov 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10886982066923 UDI-DI Date14 Sep 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK040762 Date12 Apr 2004DecidedStatusActive

Official records

From the FDA record

Device description
COMPRESSION DEVICE/ FOR TI CANNULATED TIBIA NAILS-EX
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 12 Nov 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K040762 decided 12 Apr 2004 Active
  • FDA GUDID UDI-DI 10886982066923 listed 14 Sep 2015 Listed

Recalls

2 recalls · FDA

    • Terminated Z-2051-2015 FDA Class II initiated 3 Jun 2015

    A specific part and lot number was packaged and shipped prior to the completion of a required internal inspection.

    • Terminated Z-2058-2013 FDA Class II initiated 2 Nov 2012 on shared 510(k) K040762

    Recall was initiated due to the possibility that the outer pouch was compromised. The product is packaged in two pouches; a sterile, internal pouch within an external pouch. It is the outer, external pouch that may be compromised.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

4 dated events

  1. Cleared FDA 510(k) K040762
  2. Recall initiated FDA recalls Z-2058-2013
  3. Recall initiated FDA recalls Z-2051-2015
  4. Listed FDA GUDID 10886982066923

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
EXPert
Generic name
Bone-nailing compression screw
Model / Ref / Catalog
03.010.004, 03010004
Primary DI / UDI-DI
10886982066923
510(k) Number
FDA product code
JDS
GMDN term
Bone-nailing compression screw
Device class
Class II
Regulation number
888.3030
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Similar devices

Other devices filed under FDA product code JDS (NAIL, FIXATION, BONE).

Other devices from Synthes GmbH

  • Tomofix

    Class IIb
  • 03.111.100S

    Class IIb
  • 68.134.011

    Class II
  • Volt 68.134.111

    Class II

See all devices from Synthes GmbH →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
Other properties (12, all answered No)