Expert-XL Lateral Spine BMD Acquisition and Analysis Software
by Lunar Corp.
510(k) K974437
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK974437 | Date13 Feb 1998 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- KGI
- Device Class
- Class II
- Regulation
- 21 CFR Part 892.1170
- Advisory Committee
- Radiology
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The Expert-XL Lateral Spine BMD Acquisition and Analysis Software is a bone densitometer accessory designed to acquire and analyze lateral view images of lumbar spine vertebrae. It estimates bone mineral density (BMD) in grams per square centimeter (g/cm²) using a 16-second acquisition process. The software compares results against a reference population of females aged 20–49, accounting for expected BMD decline after age 50. This device falls under the classification of a densitometer, bone as defined by regulatory nomenclature.
This software is intended for use in clinical radiology settings by trained personnel as an adjunct to the Expert-XL bone densitometer system. It is supplied as a standalone software solution, not as a sterile or single-use product, and does not require sterilization. The device operates in non-MRI environments and is not approved for MRI compatibility. No specific storage conditions are noted beyond standard software requirements. Its regulatory status includes FDA 510(k) clearance under product code KGI, with a decision date of February 13, 1998.
Other devices from Lunar
Questions
AI-generated answers, 1 Oct 2026
What is the Expert-XL Lateral Spine BMD Acquisition and Analysis Software used for?
This software is designed as an accessory for the Expert-XL bone densitometer system to acquire and analyze lateral view images of lumbar spine vertebrae. It estimates bone mineral density (BMD) in grams per square centimeter (g/cm²) and compares results against a reference population of females aged 20–49, accounting for expected BMD decline after age 50. It serves as an adjunct tool in clinical radiology settings to aid in diagnostic assessments.
How is the Expert-XL Lateral Spine BMD Acquisition and Analysis Software supplied?
The software is supplied as a standalone digital solution, not as a physical or sterile product. It does not require sterilization and is intended for use on compatible densitometer systems in clinical radiology environments by trained personnel. No additional hardware or consumables are included beyond the software installation.
Is the Expert-XL Lateral Spine BMD Acquisition and Analysis Software single-use or reusable?
The software is not a single-use product. It is designed for repeated use within a clinical setting, provided it remains installed on a properly maintained and updated system. The software’s functionality relies on the underlying hardware and system compatibility, ensuring consistent performance over time.
What are the key specifications for acquiring BMD measurements with this software?
The software acquires BMD measurements in a 16-second process for lateral spine images. It estimates bone mineral density in grams per square centimeter (g/cm²) and includes a reference comparison to a female population aged 20–49. The results account for expected BMD decline after age 50, providing clinically relevant insights for diagnostic purposes.
Are there any special storage requirements for the Expert-XL Lateral Spine BMD Acquisition and Analysis Software?
The software does not have specific storage conditions beyond standard requirements for digital systems, such as protection from physical damage, power fluctuations, and environmental factors that could compromise system performance. It should be stored on a secure, updated, and properly maintained computer system to ensure accurate and reliable operation.