F7-01
Ref M1115509Model FRAME F7-01
F7-01 (M1115509) is a patient monitoring system module rack (EU MDR Class IIb; FDA Class II) made by GE Healthcare Finland Oy, registered in EUDAMED on 20 Apr 2022 (Basic UDI-DI 8406821BUG00187HP), cleared under FDA 510(k) K213363 on 13 Apr 2022 and listed in FDA GUDID since 3 Jun 2016 (UDI-DI 00840682103978), active as of 22 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
1 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number8406821BUG00187HP 00840682103978 | Date20 Apr 2022 | StatusActive |
| United States | FDA 510(k)SESE GUDID | NumberK213363 | Date13 Apr 2022 | StatusActive |
| United States | GUDID listing GUDID | Number00840682103978 | Date3 Jun 2016 | StatusListed |
Official records
- EUDAMED public site 8406821BUG00187HP
- AccessGUDID record 00840682103978
- FDA 510(k) database K213363
From the FDA record
- Device description
- FRAME F7-01
- MRI safety
- MR Unsafe
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 8406821BUG00187HP registered 20 Apr 2022 Active
- FDA 510(k) K213363 decided 13 Apr 2022 Active
- FDA GUDID UDI-DI 00840682103978 listed 3 Jun 2016 Listed
Recalls
-
- Ongoing Z-0453-2026
Potential loss of monitoring on affected monitors when powered by certain batteries. Affected batteries can lose capability to hold charge and provide back up power. If this situation occurs, it will cause loss of patient monitoring and potentially delay recognizing patient status changes requiring treatment.
Timeline
- Listed FDA GUDID 00840682103978
- Cleared FDA 510(k) K213363
- Registered EUDAMED 8406821BUG00187HP
- Recall initiated FDA recalls Z-0453-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Patient monitoring system module rack
- Device name
- E-module Frames
- Model / Ref / Catalog
- M1115509, FRAME F7-01
- Primary DI / UDI-DI
- 00840682103978
- Basic UDI-DI
- 8406821BUG00187HP, B-00840682103978
- 510(k) Number
- FDA product code
- GWQ, CAP, DQK, NHQ, OLW, CBS, ORT, DRT, MLD, DSK, GWJ, CBR, BZL, CBQ, DSJ, CCL, OMC, CCK, BZK, DPZ, MHX, DXN, DSI, DXG, DPS, OLT, BZQ, KRB, KOI, DQA, FLL, NHP, NHO
- EMDN code
- Z1203020280 Multi-parameter monitors - hardware accessories
- GMDN term
- Patient monitoring system module rack
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 882.1400, 868.2600, 870.1425, 868.1500, 868.1620, 870.2300, 870.1025, 870.1110, 882.1900, 868.1700, 868.1730, 870.1100, 868.1720, 868.1400, 868.1850, 870.2710, 870.1130, 870.1435, 870.2340, 868.2375, 870.1915, 868.2775, 870.2700, 880.2910
- EU registration type
- Standard deviceLegacy device (under a directive)
- EU market of registration
- Finland
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Unsafe
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Manufacturer details
- EUDAMED SRN
- FI-MF-000001176
Similar devices in this category
Other devices filed under MULTI-PARAMETER MONITORS - HARDWARE ACCESSORIES.
- Reusable EEG Adult Cup Electrodes 989803105621 by Philips Medizin Systeme Böblingen GmbH
- EV1000 PC2K by Edwards Lifesciences LLC
- Activity Sensor NGS170 by SOMNOmedics AG
- ECG Cable and Leadwires BCY5-31IG by Shenzhen Best Electronics Co.,Ltd
- B1X5-F2 Second Frame 2104800-001 by GE MEDICAL SYSTEMS INFORMATION TECHNOLOGIES, INC.
- Intercostal EMG sensor SEN623 by SOMNOmedics AG
- DS1 3-WAY SPLITTER CABLE 2024565-002 by GE MEDICAL SYSTEMS INFORMATION TECHNOLOGIES, INC.
- EEG Trunk Cable 2.7 meter 989803106091 by Philips Medizin Systeme Böblingen GmbH
- Masimo Rainbow SET MCable MS27900 by Draeger Medical Systems, Inc.
- HemoSphere Vita HEMPC2K by Edwards Lifesciences LLC