Masimo Rainbow SET MCable MS27900
by Draeger Medical Systems, Inc.
Ref MS27900Model 307028VK19Z000
Masimo Rainbow SET MCable MS27900 is a general-purpose multi-parameter bedside monitor (EU MDR Class IIb; FDA Class II; FDA product code MHX, Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)) made by Draeger Medical Systems, Inc., registered in EUDAMED on 27 May 2026 (Basic UDI-DI 040486752307028VK19Z000HH), cleared under FDA 510(k) K113798 on 22 Mar 2012 and listed in FDA GUDID since 24 Oct 2015 (UDI-DI 04049098009744), active as of 23 Oct 2026. 8 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
2 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number040486752307028VK19Z000HH 04049098009744 | Date27 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04049098009744 | Date24 Oct 2015 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK113798 | Date22 Mar 2012 | StatusActive |
Official records
- EUDAMED public site 040486752307028VK19Z000HH
- AccessGUDID record 04049098009744
- FDA 510(k) database K113798
From the FDA record
- MRI safety
- MR Unsafe
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 040486752307028VK19Z000HH registered 27 May 2026 Active
- FDA 510(k) K113798 decided 22 Mar 2012 Active
- FDA GUDID UDI-DI 04049098009744 listed 24 Oct 2015 Listed
Recalls
-
- Ongoing Z-1104-2021
The Infinity M540 patient monitor may randomly reboot due to an error to correctly transmit and read the header data of files in the memory of the device. Under this situation, the device will try to reboot to mitigate the error. The device will be available again for use within 30 seconds. If this error continues and the M540 reboots three times in a time span of 10 minutes, it will enter a fail-state. A fail-state will annunciate itself with a continuous sound to alert the user. The M540 will reset to factory default and the user can manually configure and readmit the patient to continue patient monitoring.
-
- Ongoing Z-0258-2020
Cybersecurity vulnerabilities may cause device to reboot, lose alarm functionality, and/or lose communication with cockpit and/or the Infinity Network.
-
- Terminated Z-1813-2018
Software anomaly resulting in the loss of patient settings and stored patient data.
-
- Terminated Z-1382-2018
The invasive pressure visual and audible alarms may not activate.
-
- Terminated Z-0942-2018
Dual Hemo MCable Pods with Revision Index (RI) 15 and 16, which are used with the Drger Infinity Acute Care System, may permit liquid ingress inconsistent with their IPX4 rating, which could potentially result in an incorrect measured value of invasive blood pressure.
-
- Terminated Z-2734-2017
Cockpits with revision index 06 or higher that contain 4GB RAM modules may not annunciate audio or visual alarms on the Cockpit and Central Station.
-
- Terminated Z-0714-2014
After a test in which a low SpO2 (yellow) medium grade alarm initiated in neo-natal mode and was subsequently paused, the high grade life threatening SpO2 alarm (red) did not activate when the SpO2 values were decreased to reach the red alarm limit.
-
- Terminated Z-0939-2013
The displayed value for the invasive blood pressure measurement of the IACS was different than the actual patient values. Liquid ingress in the cable connection may cause inaccurate measurements. This can happen if the Dual Hemo MCable is used in a non-vertical position, a vertical position but upside down, or laying it on the floor or on the patient bed.
Timeline
- Recall initiated FDA recalls Z-0939-2013
- Recall initiated FDA recalls Z-0714-2014
- Listed FDA GUDID 04049098009744
- Recall initiated FDA recalls Z-2734-2017
- Recall initiated FDA recalls Z-0942-2018
- Recall initiated FDA recalls Z-1382-2018
- Recall initiated FDA recalls Z-1813-2018
- Recall initiated FDA recalls Z-0258-2020
- Recall initiated FDA recalls Z-1104-2021
- Registered EUDAMED 040486752307028VK19Z000HH
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Masimo Rainbow SET MCable
- Generic name
- General-purpose multi-parameter bedside monitor
- Model / reference
- MS27900, 307028VK19Z000
- Primary DI / UDI-DI
- 04049098009744
- Basic UDI-DI
- 040486752307028VK19Z000HH
- Direct marketing DI
- 04049098009744
- 510(k) Number
- FDA product code
- MHX
- EMDN code
- Z1203020280 Multi-parameter monitors - hardware accessories
- GMDN term
- General-purpose multi-parameter bedside monitor
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 870.1025
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Unsafe
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under MULTI-PARAMETER MONITORS - HARDWARE ACCESSORIES.
- CARESCAPE SpO2 2099662-001 by GE MEDICAL SYSTEMS INFORMATION TECHNOLOGIES, INC.
- Replacement inductive effort sensor (RIP) TOS080-A by SOMNOmedics AG
- FRAME F5-01 M1115512 by GE Healthcare Finland Oy
- TruSignal SpO2 MM 1.8M 5956015 by GE Healthcare Finland Oy
- Activity Sensor for Sleep/Wake detection SEN620 by SOMNOmedics AG
- HemoSphere Vita HEMPC2K by Edwards Lifesciences LLC
- Radical Docking Station RDS-3 signal extraction pulse oximeter 9172 by MASIMO CORPORATION
- PRESSURE CONTROLLER COVER PCCVR by Edwards Lifesciences LLC
- Micromed SD LTM 64 PLUS by Micromed, Inc.
- EEG CBL Lead Set Mini for 9 Elec. 989803180531 by Philips Medizin Systeme Böblingen GmbH