Skip to content

Flexitron 111861-01

by Nucletron B.V.

Flexitron 111861-01 is a medical device (FDA Class II; FDA product code JAQ, System, applicator, radionuclide, remote-controlled) made by Nucletron B.V., cleared under FDA 510(k) K070574 on 13 Apr 2007 and listed in FDA GUDID since 10 Sep 2016 (UDI-DI 08717213022379), active as of 23 Oct 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

1 closed

Documents

510(k) K070574

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number08717213022379 UDI-DI Date10 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Abbreviated NumberK070574 Date13 Apr 2007DecidedStatusActive

Official records

From the FDA record

Device description
Flexitron Transfer Tube Set for 4F Flexibles (11-20)
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K070574 decided 13 Apr 2007 Active
  • FDA GUDID UDI-DI 08717213022379 listed 10 Sep 2016 Listed

Recalls

1 recall · FDA

    • Terminated Z-0772-2020 FDA Class II initiated 18 Nov 2019

    A component failure may lead to treatment interruption or incorrect source positioning.

Timeline

3 dated events

  1. Cleared FDA 510(k) K070574
  2. Listed FDA GUDID 08717213022379
  3. Recall initiated FDA recalls Z-0772-2020

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Flexitron
Generic name
Brachytherapy system remote afterloading source transfer tube
Model / reference
111861-01
Primary DI / UDI-DI
08717213022379
510(k) Number
FDA product code
JAQ
GMDN term
Brachytherapy system remote afterloading source transfer tube
Device class
Class II
Regulation number
892.5700
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe

Similar devices

Other devices filed under FDA product code JAQ (System, applicator, radionuclide, remote-controlled).

Other devices from Nucletron B.V.

See all devices from Nucletron B.V. →

Properties

  • Prescription use
  • Convenience kit
  • Lot / batch number
Other properties (12, all answered No)