Force Feedback 475205

by Intuitive Surgical, Inc.

Force Feedback 475205 is a robotic endoscopic electrosurgical instrument (FDA Class II; FDA product code NAY, System, surgical, computer controlled instrument) made by Intuitive Surgical, Inc., cleared under FDA 510(k) K232610 on 14 Mar 2024 and listed in FDA GUDID since 21 Mar 2024 (UDI-DI 00886874120743), active as of 22 Oct 2026. 6 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

6 ongoing

This device is named in the recall

Documents

510(k) K232610

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00886874120743 UDI-DI Date21 Mar 2024ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK232610 Date14 Mar 2024DecidedStatusActive

Official records

From the FDA record

Device description
Force Feedback Fenestrated Bipolar Forceps
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K232610 decided 14 Mar 2024 Active
  • FDA GUDID UDI-DI 00886874120743 listed 21 Mar 2024 Listed

Recalls

6 recalls · 6 ongoing · FDA

    • Ongoing Z-2310-2026 FDA Class II initiated 24 Apr 2026

    Due to unintentionally activated near infrared handheld camera when attempting to turn off illumination during normal clinical workflow transitions, particularly when switching from the handheld camera to the robotic endoscope.

    • Ongoing Z-1355-2026 FDA Class II initiated 30 Dec 2025

    Robotic-assisted surgical system has Viewer Display manufactured with outdated firmware, may result in loss of one display-loss of 3D surgical field (depth perception) but 2D maintained, or loss of both displays-complete visualization loss, without fault, instruments remain active, could lead to instrument contact with tissue, resulting in injury/bleeding; may require alternate surgical modality.

    • Ongoing Z-1428-2026 FDA Class II initiated 17 Nov 2025

    An error event following the release of a software version for the surgical system that can result in loss of user interface content on an external monitor or tower monitor.

    • Ongoing Z-1232-2026 FDA Class II initiated 7 Nov 2025

    Due to a software implementation error that allowed instruments arms failing an important diagnostic test to remain in clinical use. This test was supposed to be used to detect Universal Surgical Manipulator insertion axis ball screws that exhibit the symptoms of being bent and misaligned which is a precursor to potential ball screw fatigue failure/fraction

    • Ongoing Z-1325-2025 FDA Class II initiated 26 Feb 2025

    Due to an increase in complaints concerning foot tray pedal spring failing resulting in the pedal remaining pressed

    • Ongoing Z-0964-2026 FDA Class II initiated 21 Aug 2024

    Surgical system Error 23062 due to connector1) Partially damaged "Potential problem with ergonomics: Disable - Retry " or 2) Failed "Disable Ergonomics: Viewer, headrest, armrest, and pedal tray position cannot be adjusted until da Vinci is restarted. Contact Technical Support to report the issue: Cancel-Disable" ergonomics locked until motor replaced; may lead to delay/aborted/alternate procedure

Timeline

8 dated events

  1. Cleared FDA 510(k) K232610
  2. Listed FDA GUDID 00886874120743
  3. Recall initiated FDA recalls Z-0964-2026
  4. Recall initiated FDA recalls Z-1325-2025
  5. Recall initiated FDA recalls Z-1232-2026
  6. Recall initiated FDA recalls Z-1428-2026
  7. Recall initiated FDA recalls Z-1355-2026
  8. Recall initiated FDA recalls Z-2310-2026

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Force Feedback
Generic name
Robotic endoscopic electrosurgical instrument, bipolar, reusable
Model / reference
475205
Primary DI / UDI-DI
00886874120743
FDA product code
NAY
GMDN term
Robotic endoscopic electrosurgical instrument, bipolar, reusable
Device class
Class II
Regulation number
876.1500
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
Size
Outer Diameter — 8 Millimeter

Similar devices

Other devices filed under FDA product code NAY (System, surgical, computer controlled instrument).

Other devices from Intuitive Surgical, Inc.

See all devices from Intuitive Surgical, Inc. →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (11, all answered No)