Skip to content

GE Precision Mpi

by Nrt - Nordisk Røntgen Teknik A/S

510(k) K033486

GE Precision Mpi is a medical device (FDA Class II; FDA product code OWB, Interventional Fluoroscopic X-Ray System) made by Nrt - Nordisk Røntgen Teknik A/S, cleared under FDA 510(k) K033486 on 19 Nov 2003, active as of 22 Oct 2026. 2 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

7 closed

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK033486 Date19 Nov 2003ClearedStatusActive

Official records

From the FDA record

Received by the FDA
4 Nov 2003
FDA decision
19 Nov 2003 (Substantially Equivalent)
FDA review time
15 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K033486 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

7 recalls · FDA

    • Terminated Z-2123-2015 FDA Class II initiated 12 Jun 2015 on shared 510(k) K033486

    A reported incident of a monitor that fell from the suspension. A fall of a monitor could result in an injury to a patient or operator. Recall affects the single and dual LCD monitor suspensions used on Precision 500D Classical R & F system, Precision RXi 23A/32A Analog System, Precision RXi Digital system and Precision MPi fluoroscopic imaging systems.

    • Terminated Z-0911-2014 FDA Class II initiated 12 Dec 2013

    GE Healthcare has recently become aware of a potential safety issue involving the Precision 500D, Precision MPI & Precision RXI X-ray imaging systems overhead LCD Video Monitor Suspension (Single monitor & Dual monitor). There is a potential for the locking nut to loosen out of the LCD Video Monitor Suspension yoke. This will not lead to an immediate fall of the suspended monitor since it will

    • Terminated Z-1658-2009 FDA Unclassified (pre-2012) initiated 1 May 2009 on shared 510(k) K033486

    The GE Precision MPi is in violation with 21 CFR Part 1020.32 requiring a signal audible to the fluoroscopist to sound for each passage of 5 minutes of fluoroscopic irradiation time during an examination or procedure.

    • Terminated Z-0753-2016 FDA Class II initiated 1 Jul 2008

    It was discovered that the Remote Touch Panel (RTP) of the GE Precision MPi X-ray system may not always boot up as intended and needs to be updated to properly accomplish its intended purpose.

  • 3 recalls, same reason

    • Terminated Z-2143-2008 FDA Unclassified (pre-2012) initiated 1 May 2008 on shared 510(k) K033486
    • Terminated Z-2144-2008 FDA Unclassified (pre-2012) initiated 1 May 2008 on shared 510(k) K033486
    • Terminated Z-2142-2008 FDA Unclassified (pre-2012) initiated 1 May 2008 on shared 510(k) K033486

    The Precision MPi collimator did not contain a label identifying the device as being certified to comply with applicable requirements of the x-ray performance standard.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

8 dated events

  1. Cleared FDA 510(k) K033486
  2. Recall initiated FDA recalls Z-2143-2008
  3. Recall initiated FDA recalls Z-2144-2008
  4. Recall initiated FDA recalls Z-2142-2008
  5. Recall initiated FDA recalls Z-0753-2016
  6. Recall initiated FDA recalls Z-1658-2009
  7. Recall initiated FDA recalls Z-0911-2014
  8. Recall initiated FDA recalls Z-2123-2015

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
OWB
FDA applicant
Nrt-Nordisk Rontgen Teknik A/S
Device class
Class II
Regulation
21 CFR Part 892.1650
Advisory committee
Radiology
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code OWB (Interventional Fluoroscopic X-Ray System).

Other devices from Nrt - Nordisk Røntgen Teknik A/S

See all devices from Nrt - Nordisk Røntgen Teknik A/S →