Gemini Condor

by Philips Medical Systems (Cleveland), Inc.

510(k) K081135

Gemini Condor is a medical device (FDA Class II; FDA product code KPS, System, Tomography, Computed, Emission) made by Philips Medical Systems (Cleveland), Inc., cleared under FDA 510(k) K081135 on 29 Apr 2008, active as of 22 Oct 2026. 13 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK081135 Date29 Apr 2008ClearedStatusActive

Official records

From the FDA record

Received by the FDA
21 Apr 2008
FDA decision
29 Apr 2008 (Substantially Equivalent)
FDA review time
8 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K081135 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

13 recalls · 1 ongoing · FDA

    • Ongoing Z-1989-2021 FDA Class II initiated 1 May 2021

    Significant wear of the Monitor Bracket Assembly shaft goes unrecognized could potentially lead to the Monitor Bracket Assembly detaching from the Suspension Arm and result in potential hazard for the monitor to fall while remaining attached to the cables resulting in patient, operator, bystander, or service person to serious injury.

    • Terminated Z-2199-2015 FDA Class II initiated 1 Jul 2015

    Philips has identified four (4) software defects in the Tumor LOC software application that may potentially result in irradiation of healthy tissue or non-irradiation of diseased tissue.

    • Terminated Z-1789-2015 FDA Class II initiated 6 Mar 2015

    The firm was notified that the failure of the UPS accessory devices used in conjunction with Computed Tomography X-ray systems and Diagnostic Imaging systems. may result in battery acid leakage, overheating and/or emission of fumes.

    • Terminated Z-2037-2014 FDA Class II initiated 18 Jun 2014

    When beginning a procedure to start the gantry and CT Host, a Close Estop message may appear to the operator, but disappears before action can be taken. If this occurs it results in an inability to close E-Stop and the system is not operational for clinical use. This problem occurs randomly.

    • Terminated Z-0979-2014 FDA Class II initiated 5 Dec 2013

    The TF Big Bore patient table experienced mechanical binding during horizontal table motion resulting in an automatic Emergency Stop (E-stop). An E-Stop will interrupt a current scan, resulting in an incomplete study.

    • Terminated Z-0932-2014 FDA Class II initiated 4 Dec 2013

    The PET Reconstruction Server (PRS) database may randomly lock up after the low dose CT acquisition is complete and will not allow the PET acquisition to begin, resulting in an unexpected incomplete study.

    • Terminated Z-0883-2013 FDA Class II initiated 24 Oct 2012

    Software anomaly. Philips determined that the TumorLOC software program for the referenced PET/CT X-Ray scanning systems has the capability to generate Intensity Projection data sets from respiratory gated data. A circumstance was identified by the firm whereby these generated datasets are 'flipped' and incorrectly labeled left-to-right when the are saved to disk. If the flipped Intensity Project

    • Terminated Z-2239-2012 FDA Class II initiated 8 Aug 2012

    Philips became aware of an issue relating to a UPS battery cabinet that appeared to have burned a hole through the casing on one of the batteries. Supplier of the UPS, Chloride/Emerson, determined the batteries, housed within the UPS battery cabinet, entered thermal runaway causing the battery to overheat.

    • Terminated Z-1369-2012 FDA Not yet classified initiated 26 Jan 2012

    TumorLOC will save the incorrect contour when the user saves the contour while in the edit mode, and the software does not force the user to exit the edit mode before saving. In TumorLOC, when saving while a contour is in edit mode, that contour will shift to the slice corresponding to the most recently drawn contour of the last organ in the Organ list.

    • Terminated Z-3201-2011 FDA Unclassified (pre-2012) initiated 31 May 2011

    The firm is conducting a recall/software correction to several of their GEMINI PET/CT X-ray system units in the field. The firm believes that if these software defects were to recur, it could impact the performance of reliability of the these PET/CT system units.

  • 2 recalls, same reason

    • Terminated Z-0343-2012 FDA Unclassified (pre-2012) initiated 25 Apr 2011
    • Terminated Z-0344-2012 FDA Unclassified (pre-2012) initiated 25 Apr 2011

    In response to complaints received by Philips Medical concerning certain identified software errors reported by their customers, the firm is conducting a recall/software correction to several of their GEMINI PET/CT X-ray system units in the field. The firm believes that if these software defects were to recur, it could impact the performance of reliability of the these PET/CT system units.

    • Terminated Z-2915-2011 FDA Unclassified (pre-2012) initiated 5 Aug 2009

    Two non-safety related defects have been found on the Philips GEMINI TF Big Bore running version 3.6; if these defects were to recur, it could impact the performance or reliability of the system. Philips is issuing a software update to all Philips GEMINI TF Big Bore customers to correct these defects.

Timeline

14 dated events

  1. Recall initiated FDA recalls Z-3201-2011
  2. Recall initiated FDA recalls Z-1369-2012
  3. Recall initiated FDA recalls Z-2239-2012
  4. Recall initiated FDA recalls Z-0883-2013
  5. Recall initiated FDA recalls Z-0932-2014
  6. Recall initiated FDA recalls Z-0979-2014
  7. Recall initiated FDA recalls Z-2037-2014
  8. Recall initiated FDA recalls Z-1789-2015
  9. Recall initiated FDA recalls Z-2199-2015
  10. Recall initiated FDA recalls Z-1989-2021

4 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
KPS
Device class
Class II
Regulation
21 CFR Part 892.1200
Advisory committee
Radiology
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code KPS (System, Tomography, Computed, Emission).

Other devices from Philips Medical Systems (Cleveland), Inc.

See all devices from Philips Medical Systems (Cleveland), Inc. →