Skip to content

Geneva 152005-00

by Nucletron B.V.

Geneva 152005-00 is a medical device (FDA Class II; FDA product code JAQ, System, applicator, radionuclide, remote-controlled) made by Nucletron B.V., cleared under FDA 510(k) K201272 on 16 Jul 2020 and listed in FDA GUDID since 13 Aug 2020 (UDI-DI 08717213055995), active as of 23 Oct 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

510(k) K201272

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number08717213055995 UDI-DI Date13 Aug 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK201272 Date16 Jul 2020DecidedStatusActive

Official records

From the FDA record

Device description
Intrauterine Tube 0mm
MRI safety
MR Safe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K201272 decided 16 Jul 2020 Active
  • FDA GUDID UDI-DI 08717213055995 listed 13 Aug 2020 Listed

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-2712-2026 FDA Class II initiated 3 Apr 2026

    Due to safety concerns regarding the detachment of the tip of the intrauterine tube (IU tube) that may remain within a patient.

Timeline

3 dated events

  1. Cleared FDA 510(k) K201272
  2. Listed FDA GUDID 08717213055995
  3. Recall initiated FDA recalls Z-2712-2026

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Geneva
Generic name
Cervical/intrauterine brachytherapy system applicator, remote-afterloading
Model / reference
152005-00
Primary DI / UDI-DI
08717213055995
510(k) Number
FDA product code
JAQ
GMDN term
Cervical/intrauterine brachytherapy system applicator, remote-afterloading
Device class
Class II
Regulation number
892.5700
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
MRI safety
MR Safe

Similar devices

Other devices filed under FDA product code JAQ (System, applicator, radionuclide, remote-controlled).

Other devices from Nucletron B.V.

See all devices from Nucletron B.V. →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (11, all answered No)