Hamilton-C6 160021
Ref 160021
Hamilton-C6 160021 is a neonatal/adult intensive-care ventilator (EU MDR Class IIb; FDA Class II; FDA product code CBK, Ventilator, Continuous, Facility Use) made by Hamilton Medical AG, registered in EUDAMED on 2 Sep 2026 (Basic UDI-DI 76300028PN160021ZW), cleared under FDA 510(k) K201658 on 11 Dec 2020 and listed in FDA GUDID since 26 Jan 2022 (UDI-DI 07630002808590), active as of 9 Nov 2026. 5 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
5 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number76300028PN160021ZW 07630002808590 | Date2 Sep 2026 | StatusActive |
| United States | GUDID listing GUDID | Number07630002808590 | Date26 Jan 2022 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK201658 | Date11 Dec 2020 | StatusActive |
Official records
- EUDAMED public site 76300028PN160021ZW
- AccessGUDID record 07630002808590
- FDA 510(k) database K201658
Across registries
- EUDAMED Basic UDI-DI 76300028PN160021ZW registered 2 Sep 2026 Active
- FDA 510(k) K201658 decided 11 Dec 2020 Active
- FDA GUDID UDI-DI 07630002808590 listed 26 Jan 2022 Listed
Recalls
-
- Ongoing Z-2328-2025
A mechanical defect on a printed circuit board (PCB) as a result of PCB separating process. This defect might cause the ventilator to either fail at startup (no patient involvement) or during the use of the device enter ambient state, resulting in an interruption of ventilation.
-
- Ongoing Z-2020-2024
Ventilator may enter sensor fail mode, ventilation may not re-initiate, after patient is reconnected, which may cause hypoxia, if this sequence occurs: 1)User presses O2 enrichment, 2)User disconnects endotracheal tube for open suctioning, 3)Sensor error initiated, sensor fail mode occurs, 4)Patient is re-connected with sensor fail mode active, 5) Ventilation is not re-initiated by the ventilator.
-
- Ongoing Z-1429-2023
Software error causes, safety ventilation, in which ventilation continues in the "safety ventilation" mode with audible/visible alarm - patient inputs are not monitored, if the following coincide 1) A mode change to an adaptive mode (ASV, APVcmv, APVsimv, INTELLiVENT-ASV, (S)CMV+, SIMV+), and 2) The controller and/or humidifier is connected to the ventilator and is operational.
-
- Ongoing Z-0267-2023
Due to a malfunction related to the backlight on the ventilator screen. The screen goes black for approximately 2-3 seconds, but it brightens up again when the backlight switches on again.
-
- Ongoing Z-1525-2022
Ventilator status indicator board can become loose, which could lead to water ingress (disinfectants) that may lead to technical fault alarms. Multiple technical faults in a short time may force ventilators into Safety Ventilation (blower runs constantly) or Ambient Sate (inspiratory channel/expiratory valves opened; patient breaths room air unassisted) with Panel connection lost message displayed
Timeline
- Cleared FDA 510(k) K201658
- Listed FDA GUDID 07630002808590
- Recall initiated FDA recalls Z-1525-2022
- Recall initiated FDA recalls Z-0267-2023
- Recall initiated FDA recalls Z-1429-2023
- Recall initiated FDA recalls Z-2020-2024
- Recall initiated FDA recalls Z-2328-2025
- Registered EUDAMED 76300028PN160021ZW
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Hamilton-C6
- Generic name
- Neonatal/adult intensive-care ventilator
- Model / Ref / Catalog
- 160021
- Primary DI / UDI-DI
- 07630002808590
- Basic UDI-DI
- 76300028PN160021ZW
- 510(k) Number
- FDA product code
- CBK
- EMDN code
- R9099 Respiratory and anaesthesia devices - other
- GMDN term
- Neonatal/adult intensive-care ventilator
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 868.5895
- EU registration type
- Standard device
- EU market of registration
- Austria
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Unsafe
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under RESPIRATORY AND ANAESTHESIA DEVICES - OTHER.
- 8MFA SERIES FLOWMETERS (AIR) by Precision Medical Inc
- Sprint 10845218 by CAIRE INC.
- SURVAC™ 77632 by NOVATECH SA
- Foam Stoma Protector, Tan, 2.4''Lx2.0''W (6cm x 5cm) 30 pk BE 6215 by Freudenberg Medical LLC
- SURVAC™ 77622 by NOVATECH SA
- Stroller 11933113 by CAIRE INC.
- Oropharyngeal Airways EC28010110 by Guangdong Ecan Medical Co., Ltd.
- Fleximag Max 300 - Lung Ventilator Neonate to Adult 1107240 by Magnamed Tecnologia Medica S/A
- Mouth Opener RMO0101001 by XIAMEN COMPOWER MEDICAL TECH. CO., LTD.
- tremoflo C-100 Kit - Ganshorn SpiroDef Mouthpiece Variant Edition 102079 by Thorasys Thoracic Medical Systems Inc