Hamilton-C6

by Hamilton Medical AG

510(k) K201658

Hamilton-C6 is a medical device (FDA Class II; FDA product code CBK, Ventilator, Continuous, Facility Use) made by Hamilton Medical AG, cleared under FDA 510(k) K201658 on 11 Dec 2020, active as of 22 Oct 2026. 5 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

5 ongoing

This device is named in the recall

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK201658 Date11 Dec 2020ClearedStatusActive

Official records

From the FDA record

Received by the FDA
18 Jun 2020
FDA decision
11 Dec 2020 (Substantially Equivalent)
FDA review time
176 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K201658 (openFDA), as read on 22 Oct 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

5 recalls · 5 ongoing · FDA

    • Ongoing Z-2328-2025 FDA Class I initiated 3 Jun 2025

    A mechanical defect on a printed circuit board (PCB) as a result of PCB separating process. This defect might cause the ventilator to either fail at startup (no patient involvement) or during the use of the device enter ambient state, resulting in an interruption of ventilation.

    • Ongoing Z-2020-2024 FDA Class I initiated 15 May 2024

    Ventilator may enter sensor fail mode, ventilation may not re-initiate, after patient is reconnected, which may cause hypoxia, if this sequence occurs: 1)User presses O2 enrichment, 2)User disconnects endotracheal tube for open suctioning, 3)Sensor error initiated, sensor fail mode occurs, 4)Patient is re-connected with sensor fail mode active, 5) Ventilation is not re-initiated by the ventilator.

    • Ongoing Z-1429-2023 FDA Class II initiated 14 Mar 2023

    Software error causes, safety ventilation, in which ventilation continues in the "safety ventilation" mode with audible/visible alarm - patient inputs are not monitored, if the following coincide 1) A mode change to an adaptive mode (ASV, APVcmv, APVsimv, INTELLiVENT-ASV, (S)CMV+, SIMV+), and 2) The controller and/or humidifier is connected to the ventilator and is operational.

    • Ongoing Z-0267-2023 FDA Class II initiated 22 Sep 2022

    Due to a malfunction related to the backlight on the ventilator screen. The screen goes black for approximately 2-3 seconds, but it brightens up again when the backlight switches on again.

    • Ongoing Z-1525-2022 FDA Class I initiated 27 Jun 2022

    Ventilator status indicator board can become loose, which could lead to water ingress (disinfectants) that may lead to technical fault alarms. Multiple technical faults in a short time may force ventilators into Safety Ventilation (blower runs constantly) or Ambient Sate (inspiratory channel/expiratory valves opened; patient breaths room air unassisted) with Panel connection lost message displayed

Timeline

6 dated events

  1. Cleared FDA 510(k) K201658
  2. Recall initiated FDA recalls Z-1525-2022
  3. Recall initiated FDA recalls Z-0267-2023
  4. Recall initiated FDA recalls Z-1429-2023
  5. Recall initiated FDA recalls Z-2020-2024
  6. Recall initiated FDA recalls Z-2328-2025

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
CBK
Device class
Class II
Regulation
21 CFR Part 868.5895
Advisory committee
Anesthesiology
FDA decision
SESE Substantially Equivalent

Devices cleared under K201658

1 device · FDA GUDID

Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.

Devices cleared under K201658
UDI-DISize and differences
HAMILTON-C6 160021
Hamilton Medical AG
160021 / 16002107630002808590 —On the market

Similar devices

Other devices filed under FDA product code CBK (Ventilator, Continuous, Facility Use).

Other devices from Hamilton Medical AG

See all devices from Hamilton Medical AG →