High Energy Collimator 04355124
by Siemens Medical Solutions USA, Inc.
High Energy Collimator 04355124 (4355124..) is a multi-hole nuclear medicine system collimator (FDA Class II; FDA product code KPS, System, tomography, computed, emission) made by Siemens Medical Solutions USA, Inc., cleared under FDA 510(k) K142006 on 21 Aug 2014 and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 04056869001913), active as of 23 Oct 2026. 7 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number04056869001913 | Date24 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK142006 | Date21 Aug 2014 | StatusActive |
Official records
- AccessGUDID record 04056869001913
- FDA 510(k) database K142006
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K142006 decided 21 Aug 2014 Active
- FDA GUDID UDI-DI 04056869001913 listed 24 Sep 2016 Listed
Recalls
-
- Terminated Z-2758-2016
"We have received reports of patients hair being caught in the e.cam and Symbia E patient bed up/down drive. The purpose of this letter is to remind users of the patient positioning instructions for your e.cam or Symbia E system and to inform you of an update that will be performed by your local Siemens service representative."
-
- Terminated Z-2898-2020
E. CAM and Symbia system with foresight detectors performing gated or dynamic acquisition may lose some detector time information. Our risk analysis indicates that the probability of occurrence is remote. SPECT: To detect or image the distribution of radionuclides in the body or organ, using the following techniques: planar imaging, whole body imaging, tomographic imaging for isotopes with energies up to 588keV. CT: The CT component is intended to produce cross sectional images of the body by computer reconstruction of x-ray transmission data from either the same axial place taken at different angles or spiral planes taken at different angles. SPECT+CT: Perform CT scans and nuclear imaging studies within the same instrument. To obtain attenuation corrected images and to provide registration of anatomical and physiological images within the patient's anatomy.
-
- Terminated Z-1262-2016
- Terminated Z-1263-2016
We received a customer complaint that Siemens reported via the MedWatch process (1423253-2015-00002). The result of a Hazard Analysis and CAPA investigation, we have determined that for e.cam or Symbia E systems that although the existing user manual is correct, additional supplemental instructions, with the inclusion of visual aids, may further clarify and emphasize the proper collimator change
-
- Terminated Z-0687-2016
To provide operator instruction manuals for the e.cam Dual Signature; Gamma Camera that were not sent in its entirety when the e.cam systems were refurbished and shipped to the customer.
-
- Terminated Z-2437-2015
- Terminated Z-2436-2015
- Terminated Z-2435-2015
Fuses with the improper amperage rating were installed in the Symbia S, Symbia T Series and Symbia lntevo systems. These fuses, in conjunction with a specific failure mode of the Power Controller assembly, could lead to the overheating of the assembly.
-
- Terminated Z-0208-2016
Potential failure mode related to the radial brake, where the detector was able to drift, led to a re-design of the brake redundancy circuit. The redesigned Brake Redundancy Circuit will force even a defective brake to engage in the unpowered state by applying a reverse charge to the brake and ensuring the brake has demagnetized.
Timeline
- Recall initiated FDA recalls Z-0208-2016
- Recall initiated FDA recalls Z-2437-2015
- Recall initiated FDA recalls Z-2436-2015
- Recall initiated FDA recalls Z-2435-2015
- Recall initiated FDA recalls Z-0687-2016
- Recall initiated FDA recalls Z-1262-2016
- Recall initiated FDA recalls Z-1263-2016
- Recall initiated FDA recalls Z-2898-2020
- Recall initiated FDA recalls Z-2758-2016
- Listed FDA GUDID 04056869001913
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- High Energy Collimator
- Generic name
- Multi-hole nuclear medicine system collimator, low-energy
- Model / Ref / Catalog
- 04355124, 4355124..
- Primary DI / UDI-DI
- 04056869001913
- 510(k) Number
- FDA product code
- KPS
- GMDN term
- Multi-hole nuclear medicine system collimator, low-energy
- Device class
- Class II
- Regulation number
- 892.1200
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code KPS (System, tomography, computed, emission).
- CEQUAL(TM) QUANITATIVE ANALYSIS CARDIOLITE(R) SPEC by Nuccardiac Software, Inc.
- SIM-400 SYSTEM by Scinticor, Inc.
- TAC-2, TRANSMISSION ATTENUATION CORRECTION AND DST, DST-XL GAMMA CAMERAS AND VISION POWER STATION COMPUTER, FOR USE IN S by Smv America
- VANTAGE PRO ATTENUATION CORRECTION DEVICE by Adac Laboratories
- ECAT PET/CT; ECAT LSO PET/CT; ECAT LSO PET/CT 16 by Cti Pet Systems, Inc.
- NM/CT 850, NM/CT 860 by GE Healthcare
- AUTOSPECT by Philips Medical Systems (Cleveland), Inc.
- NEURO-ECAT by Eg&G Ortec, Inc.
- SOPHY NXT by Sopha Medical Systems, Inc.
- Affinity by Hermes Medical Solutions AB