Skip to content

i-STAT 03P87-25

by Abbott Point of Care Inc.

Ref 03P87-25

i-STAT 03P87-25 is an in vitro diagnostic device (EU IVDD general IVD; FDA Class II; FDA product code JBP, Activated Whole Blood Clotting Time) made by Abbott Point of Care Inc., registered in EUDAMED on 26 Oct 2026 (Basic UDI-DI B-00054749000159), cleared under FDA 510(k) K023582 on 8 Sep 2003 and listed in FDA GUDID since 9 Sep 2016 (UDI-DI 00054749000159), active as of 7 Nov 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE IVDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

2 closed

Documents

None, self-declared

Class I: no certifier involved

510(k) K023582

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/IVDD EUDAMED NumberB-00054749000159 Basic UDI-DI 00054749000159UDI-DIDate26 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00054749000159 UDI-DI Date9 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK023582 Date8 Sep 2003DecidedStatusActive

Official records

From the FDA record

Device description
Kaolin ACT CARTRIDGE
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
Labelled as containing natural rubber latex
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00054749000159 registered 26 Oct 2026 Active
  • FDA 510(k) K023582 decided 8 Sep 2003 Active
  • FDA GUDID UDI-DI 00054749000159 listed 9 Sep 2016 Listed

Certificates

0 certificates · EUDAMED

No certifier certificate is listed. Devices of this class are self-declared by the manufacturer.

Recalls

2 recalls · FDA

    • Terminated Z-0400-2011 FDA Unclassified (pre-2012) initiated 6 Oct 2010

    Certain lots of i-STAT Celite ACT and Kaolin ACT cartridges may be difficult to fill or will not fill when attempting to transfer blood to the sample entry port of the cartridge.

    • Terminated Z-0814-2010 FDA Unclassified (pre-2012) initiated 18 Aug 2009

    Labeling discrepancy: The manual instruction state that the line should be flushed with 5 mL of saline and the first 5 mL of blood or six dead space volumes should be discarded. The Cartridge Test Information sheets that it should be 2 mL of blood - which is incorrect.

Timeline

5 dated events

  1. Cleared FDA 510(k) K023582
  2. Recall initiated FDA recalls Z-0814-2010
  3. Recall initiated FDA recalls Z-0400-2011
  4. Listed FDA GUDID 00054749000159
  5. Registered EUDAMED B-00054749000159

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
i-STAT Kaolin ACT Cartridge EUDAMED
i-STAT GUDID
Generic name
Activated clotting time (ACT) IVD, kit, clotting
Model / Ref / Catalog
03P87-25
Primary DI / UDI-DI
00054749000159 EUDAMED
10054749000156 GUDID
Basic UDI-DI
B-00054749000159
510(k) Number
FDA product code
JBP
EMDN code
W0103020804 Activated clotting time rt & poc
GMDN term
Activated clotting time (ACT) IVD, kit, clotting
Device class
Class IVD General EUDAMED
Class II GUDID
Regulation number
864.7140
EU registration type
Legacy device (under a directive)
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Primary DI / UDI-DIEUDAMED
00054749000159
GUDID
10054749000156
Device classEUDAMED
Class IVD General
GUDID
Class II

The registries describe this device under different primary UDI-DIs (EUDAMED lists 00054749000159; FDA GUDID lists 10054749000156), so their flags are not compared. Device class is stated on each registry's own scale: Class IVD General in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under HAEMOSTASIS RAPID TESTS - RT & POC.

Other devices from Abbott Point of Care Inc.

See all devices from Abbott Point of Care Inc. →

Properties

  • Single use
  • Contains latex
  • Near-patient testing
  • Professional testing
  • Lot / batch number
  • Expiration date
Other properties (20, all answered No)