Identity
- Trade Name
- ROTEM® FDA UDI
- Generic Name
- Multiple coagulation factor IVD, reagent FDA UDI
- Device Name
- The ROTEM® delta is designed for in-vitro diagnostic use by professionals in a laboratory environ-ment. The ROTEM® delta is intended to be used to provide a qualitative and quantitative indication of the coagulation state of a blood sample. For this purpose the ROTEM® delta records the clot firmness changes in a sample of citrated whole blood as the sample clots, retracts and lyses in real time. The analyzer output consists of a qualitative graphical representation (mirrored coagulation curve - clot firmness over time) and several defined numerical parameters describing the curve quantitatively. The hep-tem® assay is a semi-quantitative in vitro diagnostic assay used to inactivate heparin in patients receiving unfractionated heparin on the ROTEM® delta. To monitor the coagulation process citrated whole blood specimens are used. Clotting characteristics are described by the functional parameters Clotting Time (CT), Speed of Clot Formation (CFT and alpha angle), Clot Firmness (A20/MCF) and Clot Lysis (LOT, ML, LI(x)). FDA UDI
- Model / Reference
- hep-tem® FDA UDI
- Description
- The ROTEM® delta is designed for in-vitro diagnostic use by professionals in a laboratory environ-ment. The ROTEM® delta is intended to be used to provide a qualitative and quantitative indication of the coagulation state of a blood sample. For this purpose the ROTEM® delta records the clot firmness changes in a sample of citrated whole blood as the sample clots, retracts and lyses in real time. The analyzer output consists of a qualitative graphical representation (mirrored coagulation curve - clot firmness over time) and several defined numerical parameters describing the curve quantitatively. The hep-tem® assay is a semi-quantitative in vitro diagnostic assay used to inactivate heparin in patients receiving unfractionated heparin on the ROTEM® delta. To monitor the coagulation process citrated whole blood specimens are used. Clotting characteristics are described by the functional parameters Clotting Time (CT), Speed of Clot Formation (CFT and alpha angle), Clot Firmness (A20/MCF) and Clot Lysis (LOT, ML, LI(x)). FDA UDI
Identifiers
- Catalog Number
- 503-09-US FDA UDI
- Primary DI / UDI-DI
- 04260160470082 FDA UDI
- 510(k) Number
- K083842 FDA UDI
- FDA Product Code
- JPA FDA UDIGGN FDA UDI
- GMDN Term
- Multiple coagulation factor IVD, reagent FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 864.5425 FDA UDI
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
No
FDA UDI
Single Use
No
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
No
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
Yes
FDA UDI
Serial Number
No
FDA UDI
Expiration Date
Yes
FDA UDI
Manufacturing Date
No
FDA UDI
Category: Multiple coagulation factor IVD, reagent
Rotem® by Tem Innovations GmbH — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Similar devices
Also classified as Multiple coagulation factor IVD, reagent.
- Hemostasis System — HAEMONETICS CORPORATION · Class II
- TEG5000 HEMOSTASIS SYSTEM — HAEMONETICS CORPORATION · Class II
- TEG6s HEMOSTASIS SYSTEM — HAEMONETICS CORPORATION · Class II
- ViscoStat Clear — ULTRADENT PRODUCTS, INC. · U
- ViscoStat Clear — ULTRADENT PRODUCTS, INC. · U
- Hemochron Whole Blood Coagulation System — ACCRIVA DIAGNOSTICS HOLDINGS, INC. · Class II
- PATTERSON — PATTERSON DENTAL SUPPLY, INC. · U
- CRYOcheck™ Factor XII Deficient Plasma — Precision Biologic · Class II
Cleared under the same submission
K083842 also covers:
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Tem Innovations GmbH
Sources (1)
- FDA UDI 883c7c7c-46d8-4cc7-95e2-7285780262b3 36 fields · synced May 29, 2026