Skip to content

i-STAT 03P89-24

by Abbott Point of Care Inc.

i-STAT 03P89-24 is a medical device (FDA Class II; FDA product code GJS, Test, Time, Prothrombin) made by Abbott Point of Care Inc., cleared under FDA 510(k) K020355 on 14 May 2002 and listed in FDA GUDID since 9 Sep 2016 (UDI-DI 10054749000170), active as of 23 Oct 2026. 5 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

5 closed

Documents

510(k) K020355

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10054749000170 UDI-DI Date9 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK020355 Date14 May 2002DecidedStatusActive

Official records

From the FDA record

Device description
PT Cartridge
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
Labelled as containing natural rubber latex
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K020355 decided 14 May 2002 Active
  • FDA GUDID UDI-DI 10054749000170 listed 9 Sep 2016 Listed

Recalls

5 recalls · FDA

    • Terminated Z-2361-2015 FDA Class II initiated 15 Jun 2015

    Certain lots of PT/INR cartridges may generate a higher than typical number of PT/INR star outs potentially delaying the generation of patient results for PT/INR.

    • Terminated Z-0451-2014 FDA Class II initiated 28 Oct 2013

    Abbott Point of Care Inc (APOC) has determined that i-Stat PT/INR cartridges have the potential to exhibit incorrectly elevated INR.

    • Terminated Z-2157-2012 FDA Class II initiated 1 Mar 2012

    The i-STAT PT/INR cartridges have the potential to exhibit incorrectly elevated results.

    • Terminated Z-1996-2010 FDA Unclassified (pre-2012) initiated 5 May 2010

    A high mean bias (12-16%) was documented in 8 lots of i-STAT PT/INR cartridges. This may lead a clinician to believe that a patient is adequately anticoagulated when they are not. Inadequate anticoagluation therapy may be given and issues with clotting and/or thrombosis could occur. No reports of injury have been received.

    • Terminated Z-0364-2007 FDA Unclassified (pre-2012) initiated 12 Dec 2006

    Patients treated with the antibiotic CUBICIN can cause a concentration dependent false prolongation of prothrombin time (PT) and elevation of INR (International Normalized Ratio) when using the i-STAT PT/INR cartridges.

Timeline

7 dated events

  1. Cleared FDA 510(k) K020355
  2. Recall initiated FDA recalls Z-0364-2007
  3. Recall initiated FDA recalls Z-1996-2010
  4. Recall initiated FDA recalls Z-2157-2012
  5. Recall initiated FDA recalls Z-0451-2014
  6. Recall initiated FDA recalls Z-2361-2015
  7. Listed FDA GUDID 10054749000170

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
i-STAT
Generic name
Prothrombin time (PT) IVD, reagent
Model / Ref / Catalog
03P89-24
Primary DI / UDI-DI
10054749000170
510(k) Number
FDA product code
GJS
GMDN term
Prothrombin time (PT) IVD, reagent
Device class
Class II
Regulation number
864.7750
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code GJS (TEST, TIME, PROTHROMBIN).

Other devices from Abbott Point of Care Inc.

See all devices from Abbott Point of Care Inc. →

Properties

  • Single use
  • Contains latex
  • Lot / batch number
  • Expiration date
Other properties (11, all answered No)