Skip to content

i-STAT 06F14-01

by Abbott Point of Care Inc.

Ref 06F14-01

i-STAT 06F14-01 is a device classified as IVD General (EU), Class I (US) made by Abbott Point of Care Inc., registered in EUDAMED on 1 Sep 2026 (Basic UDI-DI B-00054749000661), cleared under FDA 510(k) K972868 on 28 Aug 1997 and listed in FDA GUDID since 23 Jun 2023 (UDI-DI 00054749000661), active as of 24 Oct 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE IVDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

None, self-declared

Class I: no certifier involved

510(k) K972868

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/IVDD EUDAMED NumberB-00054749000661 Basic UDI-DI 00054749000661UDI-DIDate1 Sep 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00054749000661 UDI-DI Date23 Jun 2023ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK972868 Date28 Aug 1997DecidedStatusActive

Official records

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00054749000661 registered 1 Sep 2026 Active
  • FDA 510(k) K972868 decided 28 Aug 1997 Active
  • FDA GUDID UDI-DI 00054749000661 listed 23 Jun 2023 Listed

Certificates

0 certificates · EUDAMED

No certifier certificate is listed. Devices of this class are self-declared by the manufacturer.

Recalls

2 recalls · 2 ongoing · FDA

  • 2 recalls, same reason

    • Ongoing Z-1314-2024 FDA Class II initiated 9 Jan 2024
    • Ongoing Z-1315-2024 FDA Class II initiated 9 Jan 2024

    Facility Critical Temperature Excursions on 08-JAN 2024 in Walk-In refrigerator due to mechanical failures, causing temperatures to fall below the validated range of 35.6 - 46.4 Degrees Fahrenheit (2 - 8 Degrees Celsius) for up to 60 minutes which could increase the probability of an incorrect test result or a delayed test result.

Timeline

5 dated events

  1. Cleared FDA 510(k) K972868
  2. Listed FDA GUDID 00054749000661
  3. Recall initiated FDA recalls Z-1314-2024
  4. Recall initiated FDA recalls Z-1315-2024
  5. Registered EUDAMED B-00054749000661

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
i-STAT
Generic name
Multiple blood gas/haemoximetry/electrolyte analyte IVD, control
Device name
i-STAT Control Level 3
Model / Ref / Catalog
06F14-01
Primary DI / UDI-DI
00054749000661
Basic UDI-DI
B-00054749000661
510(k) Number
FDA product code
JJY
EMDN code
W010106040201 Multiple parameters poc controls
GMDN term
Multiple blood gas/haemoximetry/electrolyte analyte IVD, control
Device class
Class IVD General EUDAMED
Class I GUDID
Regulation number
862.1660
EU registration type
Legacy device (under a directive)
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IVD General
GUDID
Class I

Device class is stated on each registry's own scale: Class IVD General in the EU (EUDAMED), Class I in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under MULTIPLE PARAMETERS POC.

Other devices from Abbott Point of Care Inc.

See all devices from Abbott Point of Care Inc. →

Properties

  • Single use
  • Near-patient testing
  • Professional testing
  • Lot / batch number
  • Expiration date
Other properties (21, all answered No)