IACS w/C500 MS25510
by Draeger Medical Systems, Inc.
Ref MS25510Model 2307028XK13Z00
IACS w/C500 MS25510 is a general-purpose multi-parameter bedside monitor (EU MDR Class IIb; FDA Class II; FDA product code MHX, Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms)) made by Draeger Medical Systems, Inc., cleared under FDA 510(k) K260579 on 20 Aug 2026 (1 earlier submission), registered in EUDAMED on 3 Aug 2026 (Basic UDI-DI 040486752307028XK13Z000GM) and listed in FDA GUDID since 24 Oct 2015 (UDI-DI 04049098054409), active as of 2 Nov 2026. 8 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
2 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE GUDID | NumberK260579 | Date20 Aug 2026 | StatusActive |
| European Union | CE/MDR EUDAMED | Number040486752307028XK13Z000GM 04049098054409 | Date3 Aug 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04049098054409 | Date24 Oct 2015 | StatusListed |
Official records
- EUDAMED public site 040486752307028XK13Z000GM
- AccessGUDID record 04049098054409
- FDA 510(k) database K260579
- FDA 510(k) database K113798
Across registries
- FDA 510(k) K260579 decided 20 Aug 2026 Active
- EUDAMED Basic UDI-DI 040486752307028XK13Z000GM registered 3 Aug 2026 Active
- FDA GUDID UDI-DI 04049098054409 listed 24 Oct 2015 Listed
Recalls
-
- Ongoing Z-1104-2021
The Infinity M540 patient monitor may randomly reboot due to an error to correctly transmit and read the header data of files in the memory of the device. Under this situation, the device will try to reboot to mitigate the error. The device will be available again for use within 30 seconds. If this error continues and the M540 reboots three times in a time span of 10 minutes, it will enter a fail-state. A fail-state will annunciate itself with a continuous sound to alert the user. The M540 will reset to factory default and the user can manually configure and readmit the patient to continue patient monitoring.
-
- Ongoing Z-0258-2020
Cybersecurity vulnerabilities may cause device to reboot, lose alarm functionality, and/or lose communication with cockpit and/or the Infinity Network.
-
- Terminated Z-1813-2018
Software anomaly resulting in the loss of patient settings and stored patient data.
-
- Terminated Z-1382-2018
The invasive pressure visual and audible alarms may not activate.
-
- Terminated Z-0942-2018
Dual Hemo MCable Pods with Revision Index (RI) 15 and 16, which are used with the Drger Infinity Acute Care System, may permit liquid ingress inconsistent with their IPX4 rating, which could potentially result in an incorrect measured value of invasive blood pressure.
-
- Terminated Z-2734-2017
Cockpits with revision index 06 or higher that contain 4GB RAM modules may not annunciate audio or visual alarms on the Cockpit and Central Station.
-
- Terminated Z-0714-2014
After a test in which a low SpO2 (yellow) medium grade alarm initiated in neo-natal mode and was subsequently paused, the high grade life threatening SpO2 alarm (red) did not activate when the SpO2 values were decreased to reach the red alarm limit.
-
- Terminated Z-0939-2013
The displayed value for the invasive blood pressure measurement of the IACS was different than the actual patient values. Liquid ingress in the cable connection may cause inaccurate measurements. This can happen if the Dual Hemo MCable is used in a non-vertical position, a vertical position but upside down, or laying it on the floor or on the patient bed.
Timeline
- Recall initiated FDA recalls Z-0714-2014
- Listed FDA GUDID 04049098054409
- Recall initiated FDA recalls Z-2734-2017
- Recall initiated FDA recalls Z-0942-2018
- Recall initiated FDA recalls Z-1382-2018
- Recall initiated FDA recalls Z-1813-2018
- Recall initiated FDA recalls Z-0258-2020
- Recall initiated FDA recalls Z-1104-2021
- Registered EUDAMED 040486752307028XK13Z000GM
- Cleared FDA 510(k) K260579
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Infinity Acute Care System C500 EUDAMEDIACS w/C500 GUDID
- Generic name
- General-purpose multi-parameter bedside monitor
- Model / reference
- MS25510, 2307028XK13Z00
- Primary DI / UDI-DI
- 04049098054409
- Basic UDI-DI
- 040486752307028XK13Z000GM
- Direct marketing DI
- 04049098054409
- FDA product code
- MHX
- EMDN code
- Z1203020202 Transportable/portable multi–parameter patient monitors
- GMDN term
- General-purpose multi-parameter bedside monitor
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 870.1025
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Unsafe
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under TRANSPORTABLE/PORTABLE MULTI–PARAMETER PATIENT MONITORS.
- Adt Nsl CO2 Line w/O2 STerm Lng 989803204491 by Philips Medical Systems
- Vital Signs Monitor M3 by Edan Instruments, Inc.
- MRI Patient Monitor Tesla DUO 1700001 by MIPM Mammendorfer Institut für Physik und Medizin GmbH
- MobiMed 410010331 by Ortivus MobiMed AB
- Central Monitoring System OKM 8800 by OKUMAN MEDIKAL SISTEMLER ANONIM SIRKETI
- MD2000A by Beijing Choice Electronic Technology Co., Ltd.
- Welch Allyn, Inc. 901058 73WX-B by Welch Allyn, Inc.
- Opthaem 08OPT12E by Project Engineering srl
- Vital Signs Monitor Checkme Pro by Viatom Technology Co., Ltd.
- viQtor by smartQare BV