Infinity Mcable-Analog/Sync MS20662
by Draeger Medical Systems, Inc.
Ref MS20662Model 307028XK19Z000
Infinity Mcable-Analog/Sync MS20662 is a general-purpose multi-parameter bedside monitor (EU MDR Class IIb; FDA Class II) made by Draeger Medical Systems, Inc., registered in EUDAMED on 27 May 2026 (Basic UDI-DI 040486752307028XK19Z000JP), cleared under FDA 510(k) K113798 on 22 Mar 2012 and listed in FDA GUDID since 24 Oct 2015 (UDI-DI 04049098054430), active as of 25 Oct 2026. 8 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
2 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number040486752307028XK19Z000JP 04049098054430 | Date27 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04049098054430 | Date24 Oct 2015 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK113798 | Date22 Mar 2012 | StatusActive |
Official records
- EUDAMED public site 040486752307028XK19Z000JP
- AccessGUDID record 04049098054430
- FDA 510(k) database K113798
Across registries
- EUDAMED Basic UDI-DI 040486752307028XK19Z000JP registered 27 May 2026 Active
- FDA 510(k) K113798 decided 22 Mar 2012 Active
- FDA GUDID UDI-DI 04049098054430 listed 24 Oct 2015 Listed
Recalls
-
- Ongoing Z-1104-2021
The Infinity M540 patient monitor may randomly reboot due to an error to correctly transmit and read the header data of files in the memory of the device. Under this situation, the device will try to reboot to mitigate the error. The device will be available again for use within 30 seconds. If this error continues and the M540 reboots three times in a time span of 10 minutes, it will enter a fail-state. A fail-state will annunciate itself with a continuous sound to alert the user. The M540 will reset to factory default and the user can manually configure and readmit the patient to continue patient monitoring.
-
- Ongoing Z-0258-2020
Cybersecurity vulnerabilities may cause device to reboot, lose alarm functionality, and/or lose communication with cockpit and/or the Infinity Network.
-
- Terminated Z-1813-2018
Software anomaly resulting in the loss of patient settings and stored patient data.
-
- Terminated Z-1382-2018
The invasive pressure visual and audible alarms may not activate.
-
- Terminated Z-0942-2018
Dual Hemo MCable Pods with Revision Index (RI) 15 and 16, which are used with the Drger Infinity Acute Care System, may permit liquid ingress inconsistent with their IPX4 rating, which could potentially result in an incorrect measured value of invasive blood pressure.
-
- Terminated Z-2734-2017
Cockpits with revision index 06 or higher that contain 4GB RAM modules may not annunciate audio or visual alarms on the Cockpit and Central Station.
-
- Terminated Z-0714-2014
After a test in which a low SpO2 (yellow) medium grade alarm initiated in neo-natal mode and was subsequently paused, the high grade life threatening SpO2 alarm (red) did not activate when the SpO2 values were decreased to reach the red alarm limit.
-
- Terminated Z-0939-2013
The displayed value for the invasive blood pressure measurement of the IACS was different than the actual patient values. Liquid ingress in the cable connection may cause inaccurate measurements. This can happen if the Dual Hemo MCable is used in a non-vertical position, a vertical position but upside down, or laying it on the floor or on the patient bed.
Timeline
- Recall initiated FDA recalls Z-0939-2013
- Recall initiated FDA recalls Z-0714-2014
- Listed FDA GUDID 04049098054430
- Recall initiated FDA recalls Z-2734-2017
- Recall initiated FDA recalls Z-0942-2018
- Recall initiated FDA recalls Z-1382-2018
- Recall initiated FDA recalls Z-1813-2018
- Recall initiated FDA recalls Z-0258-2020
- Recall initiated FDA recalls Z-1104-2021
- Registered EUDAMED 040486752307028XK19Z000JP
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Infinity Mcable-Analog/Sync
- Generic name
- General-purpose multi-parameter bedside monitor
- Model / reference
- MS20662, 307028XK19Z000
- Primary DI / UDI-DI
- 04049098054430
- Basic UDI-DI
- 040486752307028XK19Z000JP
- Direct marketing DI
- 04049098054430
- 510(k) Number
- FDA product code
- MSX, MHX
- EMDN code
- Z12030280 Vital signs monitoring instruments - hardware accessories
- GMDN term
- General-purpose multi-parameter bedside monitor
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 870.2300, 870.1025
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Unsafe
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
Similar devices in this category
Other devices filed under VITAL SIGNS MONITORING INSTRUMENTS - HARDWARE ACCESSORIES.
- SPO2 Reus Adult Clip Sensor M1196T 989803205911 by Philips Medizin Systeme Böblingen GmbH
- SedLine Module 867186 by Philips Medizin Systeme Böblingen GmbH
- Dream Sock (Bedtime Blue) BMRHNN67IM; PSRHNN67IM by Owlet Baby Care, Inc.
- Trolley (for medical use) MT-803 by Edan Instruments,Inc.
- Sleepiz One+ 1.0 by Sleepiz AG
- Trolley (for medical use) MT-503(S) by Edan Instruments,Inc.
- NIBP tube NIBP tube for cuff, 3m NIBP tube for cuff,3m by Edan Instruments, Inc.
- viQtor by smartQare BV
- 2601008 by Shanghai Dräger Medical Instrument Co., Ltd.
- ECG trunk cable 12-lead SinglePin Vista300 2601963 by Shanghai Draeger Medical Instrument Co., Ltd.