by Imactis

Imactis J02000 (MA-J02000) is a medical device (FDA Class II; FDA product code JAK, System, X-Ray, Tomography, Computed) made by Imactis, cleared under FDA 510(k) K162314 on 24 Apr 2018 and listed in FDA GUDID since 7 Dec 2018 (UDI-DI B681J020000), active as of 23 Oct 2026. 4 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

3 ongoing

This device is named in the recall

Documents

510(k) K162314

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing NumberB681J020000 UDI-DI Date7 Dec 2018ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK162314 Date24 Apr 2018DecidedStatusActive

Official records

From the FDA record

Device description
Navigation station of the IMACTIS® CT-NAVIGATION system
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K162314 decided 24 Apr 2018 Active
  • FDA GUDID UDI-DI B681J020000 listed 7 Dec 2018 Listed

Recalls

4 recalls · 3 ongoing · FDA

    • Ongoing Z-1590-2026 FDA Class II initiated 3 Feb 2026

    There is a potential issue that can lead to discordance between the simulated needle trajectory/tip position and the actual needle trajectory/tip position.

    • Ongoing Z-2972-2020 FDA Class II initiated 24 Aug 2020

    The firm has received reports concerning the patient fiducial disk separating from the body and users attempting to re-assemble the device. The use of a re-assembled patient fiducial could lead to inability to navigate or inaccuracies such as improper needle trajectory.

    • Ongoing Z-0838-2020 FDA Class II initiated 1 Aug 2019

    The firm has become aware that the sensor cover, a component of the single-use navigation kit may contain microbial contamination. A source of microbial contamination has been identified in a raw product used to manufacture the tip of the cover.This could result in direct exposure of the intra-cardiovascular, intra-lymphatic or neurological system to a level of endotoxin sufficient to produce a pyrogenic response.

    • Terminated Z-1264-2021 FDA Class II initiated 11 Feb 2021

    Defect in the mechanical assembly of the needle holder contained in the navigation kit. One of the 2 jaws of the needle holder does not provide gripping functionality; if the defect is not detected before use, it can cause poor needle guidance and a lack of precision during navigation causing an inaccurate needle position which could cause damage to organs or vasculature adjacent to the trajectory

Timeline

6 dated events

  1. Cleared FDA 510(k) K162314
  2. Listed FDA GUDID B681J020000
  3. Recall initiated FDA recalls Z-0838-2020
  4. Recall initiated FDA recalls Z-2972-2020
  5. Recall initiated FDA recalls Z-1264-2021
  6. Recall initiated FDA recalls Z-1590-2026

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Imactis®
Generic name
Electromagnetic surgical navigation/tracking system
Model / Ref / Catalog
J02000, MA-J02000
Primary DI / UDI-DI
B681J020000
510(k) Number
FDA product code
JAK
GMDN term
Electromagnetic surgical navigation/tracking system
Device class
Class II
Regulation number
892.1750
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe

Similar devices in this category

Other devices filed under Electromagnetic surgical navigation device tracking system.

Other devices from Imactis

  • Imactis® J00097

    Class I
  • Imactis® A10200 Open recall

    Class II
  • Imactis® I10100 Open recall

    Class II
  • Imactis® A10010 Open recall

    Class II

See all devices from Imactis →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (12, all answered No)