INOmax 10014
by Mallinckrodt Manufacturing, LLC
INOmax 10014 is a nitric oxide delivery unit (FDA Class I; FDA product code BZO, Set, Tubing And Support, Ventilator (W Harness)) made by Mallinckrodt Manufacturing, LLC, cleared under FDA 510(k) K131686 on 29 Nov 2013 and listed in FDA GUDID since 1 Feb 2023 (UDI-DI 00810055285013), active as of 22 Oct 2026.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00810055285013 | Date1 Feb 2023 | StatusListed |
| United States | FDA 510(k)SESE | NumberK131686 | Date29 Nov 2013 | StatusActive |
Official records
- AccessGUDID record 00810055285013
- FDA 510(k) database K131686
From the FDA record
- Device description
- INOmax Regulator Extension Hose
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K131686 decided 29 Nov 2013 Active
- FDA GUDID UDI-DI 00810055285013 listed 1 Feb 2023 Listed
Recalls
-
- Terminated Z-2733-2018
INOmeters affixed to the INOflo cylinders in Lot 17FP-0570 were programmed with an incorrect expiration date (11/2017). For Lot 17FP-0570, the label affixed to each INOflo cylinder has the correct expiration date noted (11/2020).
-
- Terminated Z-1076-2017
Mallinckrodt discovered that some devices may have been manufactured with an out-of-tolerance manometer which can result in in an inaccurate proportional valve calibration table in an affected device.
-
- Terminated Z-0575-2015
An issue has been identified in the INOmax DSIR system that could result in monitored Nitric Oxide (NO) concentration reporting lower than expected. This issue only pertains to those devices manufactured using a specific version of the Monitoring Circuit Board.
-
- Terminated Z-1528-2014
An anomaly impacts the monitoring system of INOmax DSIR Plus (software 3.0.0). When the integrated pneumatic backup switch is activated with low or no gas flow through the injector module, an intended NO cell failure alarm will occur. In addition, an unintended NO2 cell failure alarm may also occur. The NO/NO2 cell failure alarms are caused by an average NO/NO2 circuit concentration greater tha
Timeline
- Cleared FDA 510(k) K131686
- Recall initiated FDA recalls Z-1528-2014
- Recall initiated FDA recalls Z-0575-2015
- Recall initiated FDA recalls Z-1076-2017
- Recall initiated FDA recalls Z-2733-2018
- Listed FDA GUDID 00810055285013
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- INOmax
- Generic name
- Nitric oxide delivery unit, system-based
- Model / reference
- 10014
- Primary DI / UDI-DI
- 00810055285013
- 510(k) Number
- FDA product code
- BZO
- GMDN term
- Nitric oxide delivery unit, system-based
- Device class
- Class I
- Regulation number
- 868.5975
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code BZO (Set, Tubing And Support, Ventilator (W Harness)).
- BENNETT VOLUME VENTILATOR CIRCUIT by Ideal Medical, Inc.
- RAINCOAT by Artec Environmental Monitoring Division
- GAS SAMPLING KIT by Respiratory Support Products, Inc.
- F&P OptiPAP Junior OPTIPAPC2330 by FISHER & PAYKEL HEALTHCARE, INC.
- LIFEGUARD GAS SAMPLING LINE FOR MASS SPECTROMETRY by Lifeguard Medical Products, Inc.
- GAS SAMPLING KIT MODIFICATION by Respiratory Support Products, Inc.
- F&P FlexiTrunk BC190-05 by FISHER & PAYKEL HEALTHCARE, INC.
- L100B UNIVERSAL & L100A NIGHT PATIENT CIRCUIT by Life Products, Inc.
- Adult Flex Tubing VR017 by Vr Medical Technology
- CLEVELAND TUBING, INC. VENTILATOR HOSES by Cleveland Tubing, Inc.