INOmax 10022

by Mallinckrodt Manufacturing, LLC

INOmax 10022 is a nitric oxide delivery unit (FDA Class II; FDA product code MRN, Apparatus, Nitric Oxide Delivery) made by Mallinckrodt Manufacturing, LLC, cleared under FDA 510(k) K131686 on 29 Nov 2013 and listed in FDA GUDID since 1 Feb 2023 (UDI-DI 00810055285044), active as of 22 Oct 2026. 4 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

4 closed

Documents

510(k) K131686

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00810055285044 UDI-DI Date1 Feb 2023ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK131686 Date29 Nov 2013DecidedStatusActive

Official records

From the FDA record

Device description
Inomax transport regulator / cap assembly
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K131686 decided 29 Nov 2013 Active
  • FDA GUDID UDI-DI 00810055285044 listed 1 Feb 2023 Listed

Recalls

4 recalls · FDA

    • Terminated Z-2733-2018 FDA Class II initiated 9 Jul 2018

    INOmeters affixed to the INOflo cylinders in Lot 17FP-0570 were programmed with an incorrect expiration date (11/2017). For Lot 17FP-0570, the label affixed to each INOflo cylinder has the correct expiration date noted (11/2020).

    • Terminated Z-1076-2017 FDA Class II initiated 21 Nov 2016

    Mallinckrodt discovered that some devices may have been manufactured with an out-of-tolerance manometer which can result in in an inaccurate proportional valve calibration table in an affected device.

    • Terminated Z-0575-2015 FDA Class II initiated 17 Oct 2014

    An issue has been identified in the INOmax DSIR system that could result in monitored Nitric Oxide (NO) concentration reporting lower than expected. This issue only pertains to those devices manufactured using a specific version of the Monitoring Circuit Board.

    • Terminated Z-1528-2014 FDA Class II initiated 27 Mar 2014

    An anomaly impacts the monitoring system of INOmax DSIR Plus (software 3.0.0). When the integrated pneumatic backup switch is activated with low or no gas flow through the injector module, an intended NO cell failure alarm will occur. In addition, an unintended NO2 cell failure alarm may also occur. The NO/NO2 cell failure alarms are caused by an average NO/NO2 circuit concentration greater tha

Timeline

6 dated events

  1. Cleared FDA 510(k) K131686
  2. Recall initiated FDA recalls Z-1528-2014
  3. Recall initiated FDA recalls Z-0575-2015
  4. Recall initiated FDA recalls Z-1076-2017
  5. Recall initiated FDA recalls Z-2733-2018
  6. Listed FDA GUDID 00810055285044

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
INOmax
Generic name
Nitric oxide delivery unit, system-based
Model / reference
10022
Primary DI / UDI-DI
00810055285044
510(k) Number
FDA product code
MRN
GMDN term
Nitric oxide delivery unit, system-based
Device class
Class II
Regulation number
868.5165
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code MRN (Apparatus, Nitric Oxide Delivery).

Other devices from Mallinckrodt Manufacturing, LLC

See all devices from Mallinckrodt Manufacturing, LLC →

Properties

  • Serial number