Skip to content

Integrated Power Console 1898001LO

by Medtronic Xomed Inc

Integrated Power Console 1898001LO is a Class II device made by Medtronic Xomed Inc, cleared under FDA 510(k) K081277 on 5 Sep 2008 and listed in FDA GUDID since 16 Oct 2017 (UDI-DI 00643169931404), active as of 8 Nov 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

1 closed

Documents

510(k) K081277

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 8 Nov 2026.

Regulatory status

as of registry sync 8 Nov 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00643169931404 UDI-DI Date16 Oct 2017ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK081277 Date5 Sep 2008DecidedStatusActive

Official records

Across registries

2 registries list this device

  • FDA 510(k) K081277 decided 5 Sep 2008 Active
  • FDA GUDID UDI-DI 00643169931404 listed 16 Oct 2017 Listed

Recalls

1 recall · FDA

    • Terminated Z-0961-2022 FDA Class II initiated 15 Dec 2021

    As a result of Medtronic's integrated power console (authentication number: 222ACBZX00018000) being used with software version: v2.7.3.0, it was discovered that there was a defect that resulted in a difference between the set number of rotations and the actual number of rotations in a specific mode when the product was used with our company's M5 handpiece.

Timeline

3 dated events

  1. Cleared FDA 510(k) K081277
  2. Listed FDA GUDID 00643169931404
  3. Recall initiated FDA recalls Z-0961-2022

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Integrated Power Console
Generic name
Surgical power tool system control unit, pneumatic
Model / reference
1898001LO
Primary DI / UDI-DI
00643169931404
510(k) Number
FDA product code
ERL
GMDN term
Surgical power tool system control unit, pneumatic
Device class
Class II
Regulation number
874.4250
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Surgical power tool system control unit, pneumatic.

Other devices from Medtronic Xomed Inc

See all devices from Medtronic Xomed Inc →

Properties

  • Prescription use
  • Serial number
Other properties (13, all answered No)