Midas Rex Legend PC100
by Medtronic Powered Surgical Solutions
Ref PC100
Midas Rex Legend PC100 is a device classified as Class I in the EU and Class II in the US made by Medtronic Powered Surgical Solutions, registered in EUDAMED on 25 Sep 2026 (Basic UDI-DI 0763000B00001587J), cleared under FDA 510(k) K163182 on 23 Mar 2017 and listed in FDA GUDID since 9 Oct 2021 (UDI-DI 00763000337551), active as of 7 Nov 2026.
Active
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0763000B00001587J 00763000337551 | Date25 Sep 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00763000337551 | Date9 Oct 2021 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK163182 | Date23 Mar 2017 | StatusActive |
Official records
- EUDAMED public site 0763000B00001587J
- AccessGUDID record 00763000337551
- FDA 510(k) database K163182
Across registries
- EUDAMED Basic UDI-DI 0763000B00001587J registered 25 Sep 2026 Active
- FDA 510(k) K163182 decided 23 Mar 2017 Active
- FDA GUDID UDI-DI 00763000337551 listed 9 Oct 2021 Listed
Timeline
- Cleared FDA 510(k) K163182
- Listed FDA GUDID 00763000337551
- Registered EUDAMED 0763000B00001587J
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Midas Rex Legend
- Generic name
- Surgical power tool system control unit, pneumatic
- Model / reference
- PC100
- Primary DI / UDI-DI
- 00763000337551
- Basic UDI-DI
- 0763000B00001587J
- 510(k) Number
- FDA product code
- HBB
- EMDN code
- S010499 Sterilisation containers - other
- GMDN term
- Surgical power tool system control unit, pneumatic
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 882.4370
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- High-level Disinfectant
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class I | Class II |
| Sterilise before use | No | Yes |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Sterilise before use UDI-DI 00763000337551: EUDAMED states No, FDA GUDID states Yes.
Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Similar devices in this category
Other devices filed under CONTAINERS FOR STERILISATION.
- Straumann® ProClean™ Cassette (041.800 ; 041.801) Storage Systems / Cassettes 041.802 by Institut Straumann AG
- ActivSight Imaging Module Tray for VHP AS-IMT001 by Activ Surgical, Inc.
- Sentire Surgical System AITY5 by Cornerstone Technology (Shenzhen) Limited
- PST Corp. 6134A by Plastic Sterilizing Tray Corporation
- Stryker Universal Select Sterilization Tray System by Paragon Medical Inc.
- PST Corp. 2526S by Plastic Sterilizing Tray Corporation
- ACUMED 80-4062 by ACUMED LLC
- The Hinge Pediatric Plating System HPDG110 by ORTHOPEDIATRICS CANADA ULC
- Fix Konisch Surgical Tray FK6301 by MEDIGMA BIOMEDICAL GMBH
- Endoscope container with lid 80-694-18 by Spiggle & Theis Medizintechnik GmbH