Intelli-C Accessory 03282220
by Nrt - Nordisk Røntgen Teknik A/S
Part of a family of 17 devices: see the family page
Ref 03282220Model CFP Accessories
Intelli-C Accessory 03282220 is a basic bed mattress (EU MDR Class I; FDA Class II) made by Nrt - Nordisk Røntgen Teknik A/S, registered in EUDAMED on 21 May 2026 (Basic UDI-DI 571346413200AG), cleared under FDA 510(k) K173631 on 11 Jul 2018 and listed in FDA GUDID since 1 May 2019 (UDI-DI 05713464000350), active as of 22 Oct 2026. 4 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
4 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number571346413200AG 05713464000350 | Date21 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number05713464000350 | Date1 May 2019 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK173631 | Date11 Jul 2018 | StatusActive |
Official records
- EUDAMED public site 571346413200AG
- AccessGUDID record 05713464000350
- FDA 510(k) database K173631
From the FDA record
- Device description
- A long mattress for the Intelli-C X-ray system with a strap, for fixating the mattress when the table is tilted.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 571346413200AG registered 21 May 2026 Active
- FDA 510(k) K173631 decided 11 Jul 2018 Active
- FDA GUDID UDI-DI 05713464000350 listed 1 May 2019 Listed
Recalls
-
- Ongoing Z-1784-2024
X-ray system C-arm may experience uncontrolled motion if 1) AC motor controller firmware has a faulty setting, 2) the Motor/gear assembly is worn, 3) CAT movement is driven at maximum speed and angulated more than 75 deg. from vertical, and 4) the emergency stop or touch guard is activated during the breaking sequence, which could lead to the C-arm hitting the patient or operator.
-
- Ongoing Z-1669-2023
- Ongoing Z-1668-2023
There is a potential that the drive shaft in the detector up/down (IDE) movement of the X-Ray machine may break which causes the detector to move until it is stopped by the movement end-stop.
-
- Ongoing Z-0526-2022
Friction rubber block in the clamping mechanism was missing in the Footrest. It may slip down along the patient table while in use with a patient. This accessory is designed to use with Intelli-C, Right and Intelli-C, Left.
Timeline
- Cleared FDA 510(k) K173631
- Listed FDA GUDID 05713464000350
- Recall initiated FDA recalls Z-0526-2022
- Recall initiated FDA recalls Z-1669-2023
- Recall initiated FDA recalls Z-1668-2023
- Recall initiated FDA recalls Z-1784-2024
- Registered EUDAMED 571346413200AG
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Mattress, Long EUDAMEDIntelli-C Accessory GUDID
- Generic name
- Basic bed mattress
- Model / reference
- 03282220, CFP Accessories
- Primary DI / UDI-DI
- 05713464000350
- Basic UDI-DI
- 571346413200AG
- Direct marketing DI
- 05713464000350
- 510(k) Number
- FDA product code
- OWB, JAA
- EMDN code
- Z11039080 Various radiodiagnostic and interventional instruments - hardware accessories
- GMDN term
- Basic bed mattress
- Device class
- Class I EUDAMEDClass II GUDID
- Regulation number
- 892.1650
- EU registration type
- Standard device
- EU market of registration
- Denmark
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class I | Class II |
Similar devices in this category
Other devices filed under VARIOUS RADIODIAGNOSTIC AND INTERVENTIONAL INSTRUMENTS - HARDWARE ACCESSORIES.
- AEC Chamber 143 00 06 by VacuTec Meßtechnik GmbH
- SU-2000 N/A by SHINYOUNG FOR M CO., LTD.
- Remote Control Holder 989001085352 by Philips Medical Systems DMC GmbH
- Traumaarm 1300 by Medizintechnik St. Egidien GmbH
- Added filter DR-XD 1000 FILTER E by FUJIFILM CORPORATION
- AEC Chamber 141 00 20 by VacuTec Meßtechnik GmbH
- ACIST Pro AngioTouch Module 50' 019312 by ACIST Medical Systems, Inc.
- Babixhalter 2000 by Medizintechnik St. Egidien GmbH
- Ion Tomosynthesis Board 380456 by Intuitive Surgical, Inc.
- EXPLORER AIR II 8002 by SurgVision GmbH