Skip to content

Interstitial Ring CT/MR Applicator 110331A02-01

by Nucletron B.V.

Interstitial Ring CT/MR Applicator 110331A02-01 is a medical device (FDA Class II; FDA product code JAQ, System, applicator, radionuclide, remote-controlled) made by Nucletron B.V., cleared under FDA 510(k) K091154 on 18 May 2009 and listed in FDA GUDID since 23 Nov 2016 (UDI-DI 08717213036000), active as of 23 Oct 2026.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 23 Oct 2026

Documents

510(k) K091154

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number08717213036000 UDI-DI Date23 Nov 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK091154 Date18 May 2009DecidedStatusActive

Official records

From the FDA record

Device description
Interstitial CT/MR Applicator Set 30 mm
MRI safety
MR Safe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K091154 decided 18 May 2009 Active
  • FDA GUDID UDI-DI 08717213036000 listed 23 Nov 2016 Listed

Timeline

2 dated events

  1. Cleared FDA 510(k) K091154
  2. Listed FDA GUDID 08717213036000

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Interstitial Ring CT/MR Applicator
Generic name
Cervical/intrauterine brachytherapy system applicator, remote-afterloading
Model / reference
110331A02-01
Primary DI / UDI-DI
08717213036000
510(k) Number
FDA product code
JAQ
GMDN term
Cervical/intrauterine brachytherapy system applicator, remote-afterloading
Device class
Class II
Regulation number
892.5700
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
MRI safety
MR Safe
Size
Angle — 60.0 degree
Outer Diameter — 30.0 Millimeter

Similar devices

Other devices filed under FDA product code JAQ (System, applicator, radionuclide, remote-controlled).

Other devices from Nucletron B.V.

See all devices from Nucletron B.V. →

Properties

  • Sterilise before use
  • Prescription use
  • Convenience kit
  • Lot / batch number
Other properties (11, all answered No)