Skip to content

Interventional Angiography System Infx-8000C

by Canon Inc.

Ref INFX-8000CModel INFX-8000C, INFX-8000F, etc.

Interventional Angiography System Infx-8000C is a stationary angiographic x-ray system (EU MDR Class IIb; FDA Class II) made by Canon Inc., registered in EUDAMED on 15 Jun 2026 (Basic UDI-DI 4987670A0101QY), cleared under FDA 510(k) K181804 on 2 Aug 2018 (2 earlier submissions) and listed in FDA GUDID since 1 Sep 2016 (UDI-DI 04987670100192), active as of 22 Oct 2026. 7 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

5 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number4987670A0101QY Basic UDI-DI 04987670100192UDI-DIDate15 Jun 2026RegisteredStatusActive
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK181804 Date2 Aug 2018DecidedStatusActive
United StatesGUDID listing GUDID Number04987670100192 UDI-DI Date1 Sep 2016ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
INTERVENTIONAL ANGIOGRAPHY SYSTEM
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 4987670A0101QY registered 15 Jun 2026 Active
  • FDA 510(k) K181804 decided 2 Aug 2018 Active· +2 more in the status table
  • FDA GUDID UDI-DI 04987670100192 listed 1 Sep 2016 Listed

Recalls

8 recalls · 5 ongoing · FDA

    • Ongoing Z-1289-2022 FDA Class II initiated 3 May 2022

    CT operation may be restricted by an interlock which is a result of an system error and the CT system may stop operating properly after an attempt to cancel the error message has been initiated.

    • Ongoing Z-0492-2022 FDA Class II initiated 20 Dec 2021

    Abnormal images such as horizontal stripes may be displayed and recovery may not not be possible by restarting the system. The worst case scenario is an operator who is working without a workable image may remove a catheter from the patient's blood vessel and damage the blood vessel.

    • Ongoing Z-1175-2021 FDA Class II initiated 5 Feb 2021

    The x-ray irradiation field may shift with respect to image receiving surface displayed on the screen at some C-arm angles.

    • Ongoing Z-1270-2021 FDA Class II initiated 8 Dec 2020

    System table may tilt because the bolts that fasten the vertical column and the table top tilting drive unit may become loose.

    • Ongoing Z-2326-2020 FDA Class II initiated 3 Mar 2020

    Bolts holding the longitudinal movement of catheterization tables may be loose, which may lead to table surface/top tilting.

    • Terminated Z-0532-2021 FDA Class II initiated 8 Oct 2020

    There is a potential that the cable of the Flat panel detector may break during a procedure which may cause the x-ray device to stop before the examination is completed. This could result in a delay with procedure and/or potential damage to the patients blood vessels due to removal without visibility.

    • Terminated Z-0843-2018 FDA Class II initiated 29 Dec 2017

    During an examination a device error occurred and the ceiling drive operation was disabled. It was found that the fastening bolts of the driving portion of the ceiling drive loosened cause the error.

    • Terminated Z-0994-2013 FDA Class II initiated 8 Nov 2012 on shared 510(k) K113052

    Lost and incorrect images. When using the "F-Rec" fluoroscopy image acquisition recording option in the "manual mode" an infrequent software error may cause images from another study to be displayed on the monitor. The acquired images may be lost requiring additional image acquisitions to be performed.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

13 dated events

  1. Listed FDA GUDID 04987670100192
  2. Recall initiated FDA recalls Z-0843-2018
  3. Cleared FDA 510(k) K181804
  4. Recall initiated FDA recalls Z-2326-2020
  5. Recall initiated FDA recalls Z-0532-2021
  6. Recall initiated FDA recalls Z-1270-2021
  7. Recall initiated FDA recalls Z-1175-2021
  8. Recall initiated FDA recalls Z-0492-2022
  9. Recall initiated FDA recalls Z-1289-2022
  10. Registered EUDAMED 4987670A0101QY

3 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Interventional Angiography System
Generic name
Stationary angiographic x-ray system, digital
Model / reference
INFX-8000C, INFX-8000F, etc.
Primary DI / UDI-DI
04987670100192
Basic UDI-DI
4987670A0101QY
FDA product code
JAA, OWB
EMDN code
Z11030102 Stationary angiography systems for angiographic and cardiologic studies
GMDN term
Stationary angiographic x-ray system, digital
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
892.1650
EU registration type
Standard device
EU market of registration
France
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under STATIONARY ANGIOGRAPHY SYSTEMS FOR ANGIOGRAPHIC AND CARDIOLOGIC STUDIES.

Other devices from Canon Inc.

See all devices from Canon Inc. →

Properties

  • Serial number
Other properties (24, all answered No)