ARTIS icono ceiling

by Siemens Healthcare GmbH

Ref 11328100Model MDR_01_IIb_FOR_ACDV_ARTIS icono/pheno

ARTIS icono ceiling (11328100) is a stationary angiographic x-ray system (EU MDR Class IIb; FDA Class II) made by Siemens Healthcare GmbH, registered in EUDAMED on 27 Apr 2026 (Basic UDI-DI 0405686900146UY), cleared under FDA 510(k) K254173 on 24 Apr 2026 (2 earlier submissions) and listed in FDA GUDID since 1 Oct 2022 (UDI-DI 04056869295923), active as of 25 Oct 2026. 14 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

14 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 25 Oct 2026.

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0405686900146UY Basic UDI-DI 04056869295923UDI-DIDate27 Apr 2026RegisteredStatusActive
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK254173 Date24 Apr 2026DecidedStatusActive
United StatesGUDID listing GUDID Number04056869295923 UDI-DI Date1 Oct 2022ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0405686900146UY registered 27 Apr 2026 Active
  • FDA 510(k) K254173 decided 24 Apr 2026 Active· +2 more in the status table
  • FDA GUDID UDI-DI 04056869295923 listed 1 Oct 2022 Listed

Recalls

14 recalls · 14 ongoing · FDA

    • Ongoing Z-2648-2026 FDA Class II initiated 8 Jun 2026

    Potential issue with the Display ceiling suspension (DCS Fix XL) that holds the monitor in place. Over time some screws that keep the monitor attached to the suspension may gradually loosen.

  • 3 recalls, same reason

    • Ongoing Z-2641-2026 FDA Class II initiated 20 May 2026
    • Ongoing Z-2642-2026 FDA Class II initiated 20 May 2026
    • Ongoing Z-2643-2026 FDA Class II initiated 20 May 2026

    Potential for loss of movement capability after adjusting the detector lift height to its maximum or minimum limits.

    • Ongoing Z-1814-2026 FDA Class II initiated 12 Mar 2026

    During 3D acquisitions, lighter and darker patient images may be captured, which may result in less accurate 3D reconstruction. The variation of brightness is a result of a constant unregulated medium dose and the angular change of patient diameter caused by rotational acquisition. This may result in unintentional low-dose radiation exposure to a patient.

    • Ongoing Z-1653-2026 FDA Class II initiated 10 Mar 2026

    During patient examinations, the system may sporadically display a major increase of the x-ray dose applied to the patient. Despite the reported dose showing significantly higher, the actual applied x-ray dose levels are in accordance with the system settings and imaging conditions, as well as the applicable regulatory requirements.

  • 2 recalls, same reason

    • Ongoing Z-2205-2026 FDA Class II initiated 9 Mar 2026
    • Ongoing Z-2206-2026 FDA Class II initiated 9 Mar 2026

    During patient examinations, the system may sporadically display a 0 x-ray dose administered to the patient. This behavior has only been observed during fluoroscopy and/or single-frame acquisitions. Despite the reported x-ray dose showing 0, an actual x-ray dose is applied to the patient.

    • Ongoing Z-2529-2025 FDA Class II initiated 12 Aug 2025

    Limited system movements after startup .

  • 3 recalls, same reason

    • Ongoing Z-2020-2025 FDA Class II initiated 15 May 2025
    • Ongoing Z-2021-2025 FDA Class II initiated 15 May 2025
    • Ongoing Z-2022-2025 FDA Class II initiated 15 May 2025

    In very rare situations, communication between the sensor measuring dose applied to the area and the corresponding software fails. As a result of the failure, the system may incorrectly report an application of a high dose.

    • Ongoing Z-2241-2024 FDA Class II initiated 26 Jun 2024

    A potential issue with ARTIS icono systems equipped with a small detector and a corresponding collimator (model # 10843101) was identified. In very rare situations, the first x-ray release following patient registration may be performed with incorrect copper prefiltration. If the described issue occurs, the applied radiation dose rate may be higher than intended by the user.

    • Ongoing Z-0523-2024 FDA Class II initiated 17 Oct 2023 UDI-DI 04056869295923 listed

    Potential hardware issue for ARTIS icono ceiling system: collision sensor may falsely signal non-existing collisions for up to half an hour when the system is switched off for a longer time (e.g., overnight) and switched on. During this time, system movement is only possible with the "override" function with very slow speed and without further collision protection. This may lead to temporary unavailability of the system for diagnostic and therapeutic usage.

Timeline

19 dated events

  1. Recall initiated FDA recalls Z-2205-2026
  2. Recall initiated FDA recalls Z-2206-2026
  3. Recall initiated FDA recalls Z-1653-2026
  4. Recall initiated FDA recalls Z-1814-2026
  5. Cleared FDA 510(k) K254173
  6. Registered EUDAMED 0405686900146UY
  7. Recall initiated FDA recalls Z-2641-2026
  8. Recall initiated FDA recalls Z-2642-2026
  9. Recall initiated FDA recalls Z-2643-2026
  10. Recall initiated FDA recalls Z-2648-2026

9 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
Stationary angiographic x-ray system, digital
Device name
MDR_01_IIb_FOR_ACDV_ARTIS icono/pheno
Model / reference
MDR_01_IIb_FOR_ACDV_ARTIS icono/pheno, 11328100
Primary DI / UDI-DI
04056869295923
Basic UDI-DI
0405686900146UY
FDA product code
IZI, JAA, OWB, JAK
EMDN code
Z11030102 Stationary angiography systems for angiographic and cardiologic studies
GMDN term
Stationary angiographic x-ray system, digital
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
892.1600, 892.1650, 892.1750
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
DE-MF-000006122

Similar devices in this category

Other devices filed under STATIONARY ANGIOGRAPHY SYSTEMS FOR ANGIOGRAPHIC AND CARDIOLOGIC STUDIES.

Other devices from Siemens Healthcare GmbH

See all devices from Siemens Healthcare GmbH →

Properties

  • Measuring function
  • Prescription use
  • Serial number
Other properties (22, all answered No)