JOWIRE ASAHI PTCA CATHETER GUIDE WIRES - 141002

by Jomed, Inc.

510(k) K031277

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK031277 Date14 May 2003ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DQX
Device Class
Class II
Regulation
21 CFR Part 870.1330
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Jowire Asahi PTCA Catheter Guide Wires are flexible, atraumatic-tipped guide wires designed to assist in the placement of balloon dilatation catheters during percutaneous transluminal coronary angioplasty (PTCA). These wires feature a composite core construction for enhanced tip durability and torque performance, ensuring reliable navigation through complex coronary anatomy.

Supplied sterile and intended for single-use, these guide wires are classified as Class II devices under FDA regulations and hold a 510(k) clearance (K031277). They are intended for use in interventional cardiology settings and must be handled according to sterile procedures. Each model is identified by its specific reference code and is not MRI-compatible.

Other devices from Jomed AG

See all devices from Jomed AG →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What specific clinical procedure are these guide wires designed to assist with, and why is their tip design important?

    These guide wires are designed to assist in the placement of balloon dilatation catheters during percutaneous transluminal coronary angioplasty (PTCA), a procedure used to open narrowed coronary arteries. The atraumatic-tipped design ensures minimal risk of vessel damage during navigation through complex coronary anatomy, which is critical for safe and effective angioplasty.

  • Are these guide wires reusable, or are they intended for single-use only? How does this affect their handling?

    These guide wires are intended for single-use only and are supplied sterile. This design choice reduces infection risks and ensures consistent performance, requiring clinicians to follow strict sterile procedures during use and dispose of them after a single procedure.

  • What distinguishes the different models (e.g., AG145300 vs. 14M350) of these guide wires, and how might a clinician choose between them?

    Each model is differentiated by its reference code, which likely corresponds to variations in length, tip flexibility, or core construction (e.g., torque performance or tip durability). While the exact specifications aren’t detailed here, the composite core design suggests these variations may optimize navigation for different coronary anatomies or procedural needs. Clinicians would select a model based on procedural requirements, such as vessel tortuosity or lesion complexity.

  • Can these guide wires be used in an MRI environment, and if not, what precautions should be taken?

    No, these guide wires are not MRI-compatible. If MRI imaging is required post-procedure, the wires must be removed from the patient first, as metallic components could interfere with MRI fields or pose safety risks during scanning.

  • What storage conditions should be followed to maintain the sterility and performance of these guide wires?

    Since they are supplied sterile, they should be stored in their original packaging until use, protected from contamination, moisture, and extreme temperatures. Avoid exposure to direct sunlight or mechanical damage, as this could compromise sterility or structural integrity before use.