JOWIRE ASAHI PTCA CATHETER GUIDE WIRES - 14M350
by Jomed, Inc.
510(k) K031277
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK031277 | Date14 May 2003 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DQX
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.1330
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 19 Sep 2026
The Jowire Asahi PTCA Catheter Guide Wires are flexible, atraumatic-tipped guide wires designed to assist in the placement of balloon dilatation catheters during percutaneous transluminal coronary angioplasty (PTCA). These wires feature a composite core construction for enhanced tip durability and torque performance, ensuring reliable navigation through complex coronary anatomy.
Supplied sterile and intended for single-use, these guide wires are classified as Class II devices under FDA regulations and hold a 510(k) clearance (K031277). They are intended for use in interventional cardiology settings and must be handled according to sterile procedures. Each model is identified by its specific reference code and is not MRI-compatible.
Other devices from Jomed AG
Questions
AI-generated answers, 19 Sep 2026
What specific clinical procedure are these guide wires designed to assist with, and why is their tip design important?
These guide wires are designed to assist in the placement of balloon dilatation catheters during percutaneous transluminal coronary angioplasty (PTCA), a procedure used to open narrowed coronary arteries. The atraumatic-tipped design ensures minimal risk of vessel damage during navigation through complex coronary anatomy, which is critical for safe and effective angioplasty.
Are these guide wires reusable, or are they intended for single-use only? How does this affect their handling?
These guide wires are intended for single-use only and are supplied sterile. This design choice reduces infection risks and ensures consistent performance, requiring clinicians to follow strict sterile procedures during use and dispose of them after a single procedure.
What distinguishes the different models (e.g., AG145300 vs. 14M350) of these guide wires, and how might a clinician choose between them?
Each model is differentiated by its reference code, which likely corresponds to variations in length, tip flexibility, or core construction (e.g., torque performance or tip durability). While the exact specifications aren’t detailed here, the composite core design suggests these variations may optimize navigation for different coronary anatomies or procedural needs. Clinicians would select a model based on procedural requirements, such as vessel tortuosity or lesion complexity.
Can these guide wires be used in an MRI environment, and if not, what precautions should be taken?
No, these guide wires are not MRI-compatible. If MRI imaging is required post-procedure, the wires must be removed from the patient first, as metallic components could interfere with MRI fields or pose safety risks during scanning.
What storage conditions should be followed to maintain the sterility and performance of these guide wires?
Since they are supplied sterile, they should be stored in their original packaging until use, protected from contamination, moisture, and extreme temperatures. Avoid exposure to direct sunlight or mechanical damage, as this could compromise sterility or structural integrity before use.