K-Wire Depth Gauge 110018535

by Biomet Orthopedics, Inc.

Ref 110018535

K-Wire Depth Gauge 110018535 is a surgical depth gauge (EU MDD Class I; FDA Class II; FDA product code HWC, Screw, fixation, bone) made by Biomet Orthopedics, Inc., registered in EUDAMED on 23 Oct 2026 (Basic UDI-DI B-00887868467240), cleared under FDA 510(k) K190035 on 7 Feb 2019 (1 earlier submission) and listed in FDA GUDID since 2 Apr 2021 (UDI-DI 00887868467240), active as of 7 Nov 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

2 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00887868467240 Basic UDI-DI 00887868467240UDI-DIDate23 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00887868467240 UDI-DI Date2 Apr 2021ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Special NumberK190035 Date7 Feb 2019DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00887868467240 registered 23 Oct 2026 Active
  • FDA 510(k) K190035 decided 7 Feb 2019 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00887868467240 listed 2 Apr 2021 Listed

Recalls

2 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-1302-2019 FDA Class II initiated 28 Mar 2019
    • Terminated Z-1303-2019 FDA Class II initiated 28 Mar 2019

    There is a potential of fracture, bending or shearing of the driver.

Timeline

6 dated events

  1. Cleared FDA 510(k) K142658
  2. Cleared FDA 510(k) K190035
  3. Recall initiated FDA recalls Z-1302-2019
  4. Recall initiated FDA recalls Z-1303-2019
  5. Listed FDA GUDID 00887868467240
  6. Registered EUDAMED B-00887868467240

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
K-Wire Depth Gauge
Generic name
Surgical depth gauge, reusable
Device name
MFA_Forefoot FRS_Depth Gauge
Model / Ref / Catalog
110018535
Primary DI / UDI-DI
00887868467240
Basic UDI-DI
B-00887868467240
510(k) Number
FDA product code
HWC
EMDN code
L091001 Instruments for insertion and extraction of materials for osteosynthesis, reusable
GMDN term
Surgical depth gauge, reusable
Device class
Class I EUDAMED
Class II GUDID
Regulation number
888.3040
EU registration type
Legacy device (under a directive)
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under INSTRUMENTS FOR INSERTION AND EXTRACTION OF MATERIALS FOR OSTEOSYNTHESIS, REUSABLE.

Other devices from Biomet Orthopedics, Inc.

See all devices from Biomet Orthopedics, Inc. →

Properties

  • Sterilise before use
  • Reusable
  • Prescription use
  • Lot / batch number
Other properties (21, all answered No)