Legion E0014828-2
Legion E0014828-2 is a bone punch (FDA Class II; FDA product code MBH) made by Smith & Nephew, Inc., cleared under FDA 510(k) K121393 on 7 Aug 2012 and listed in FDA GUDID since 16 Jan 2016 (UDI-DI 00885556630341), active as of 23 Oct 2026. 4 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00885556630341 | Date16 Jan 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK121393 | Date7 Aug 2012 | StatusActive |
Official records
- AccessGUDID record 00885556630341
- FDA 510(k) database K121393
From the FDA record
- Device description
- LEFT MEDIAL PLUS FIN PUNCH SIZE 3-4
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- FDA 510(k) K121393 decided 7 Aug 2012 Active
- FDA GUDID UDI-DI 00885556630341 listed 16 Jan 2016 Listed
Recalls
-
- Ongoing Z-0878-2020
Multiple lots of LEGION AP Femoral Cutting Blocks were manufactured with an oversize green plunger hole and therefore do not meet their design specifications.
-
- Terminated Z-0200-2019
One lot of the Legion AP femoral cutting block, size 6, was manufactured with an oversized spring.
-
- Terminated Z-2163-2018
One lot of GENESIS II 13 mm tibial punches are 2 mm smaller than specification.
-
- Terminated Z-1902-2018
A single lot of GENESIS II FEMORAL FIVE DEGREE VALGUS BUSHING due to a laser mark labeling error. The left valgus bushing was incorrectly laser marked as right and vice versa.
Timeline
- Cleared FDA 510(k) K121393
- Listed FDA GUDID 00885556630341
- Recall initiated FDA recalls Z-1902-2018
- Recall initiated FDA recalls Z-2163-2018
- Recall initiated FDA recalls Z-0200-2019
- Recall initiated FDA recalls Z-0878-2020
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Legion
- Generic name
- Bone punch, reusable
- Model / Ref / Catalog
- E0014828-2
- Primary DI / UDI-DI
- 00885556630341
- 510(k) Number
- FDA product code
- MBH
- GMDN term
- Bone punch, reusable
- Device class
- Class II
- Regulation number
- 888.3565
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Similar devices
Other devices filed under FDA product code MBH (PROSTHESIS, KNEE, PATELLO/FEMOROTIBIAL, SEMI-CONSTRAINED, UNCEMENTED, POROUS, COATED, POLYMER/METAL/POLYMER).
- APEX Revision Knee KP-43100 by OMNIlife science, Inc.
- APEX Revision Knee KC-50150 by OMNIlife science, Inc.
- ADVANCE Porous Coated Spiked Tibial Base by MicroPort Orthopedics Inc.
- PHYSICA LMC 6536.54.A10 by Limacorporate
- PHYSICA LMC 6537.54.812 by Limacorporate
- Persona® 42-5891-059-00 by Zimmer, Inc.
- Beacon Knee System by Signal Medical Corp.
- Persona® 42-5846-050-12 by Zimmer, Inc.
- U2™ Knee 2303-6016 by UNITED ORTHOPEDIC CORP.
- Triathlon Total Knee System - Triathlon X3 Medial Stabilized Tibial Bearing Insert by Howmedica Osteonics Corp., Dba Stryker Orthopaedics