Lutonix Drug Coated Balloon PTA Catheter
by Lutonix
PMA P130024
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA PMAAPPR | NumberP130024 | Date9 Oct 2014 | StatusActive |
Recalls
No FDA recalls found in the data synced 6 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA PMA Active
Specification
- Full name
- Lutonix Drug Coated Balloon (Dcb)
- Trade Name
- Lutonix Drug Coated Balloon PTA Cateter
- Generic Name
- Drug-Eluting Peripheral Transluminal Angioplasty Catheter
- PMA Number
- FDA Product Code
- ONU
- Device Class
- Class III
- Advisory Committee
- Cardiovascular
- FDA Decision
- APPR Approved
Overview
AI-generated summary, 18 Sep 2026
The Lutonix Drug Coated Balloon PTA Catheter is a Drug-Eluting Peripheral Transluminal Angioplasty Catheter, designed for percutaneous transluminal angioplasty (PTA) of de novo or restenotic lesions in native superficial femoral or popliteal arteries. It delivers a drug coating to the arterial wall during inflation, aiding in vessel dilation and reducing restenosis risk in vessels with reference diameters of 4–6 mm and lesion lengths up to 150 mm.
This device is supplied as a single-use, sterile catheter and is intended for use after pre-dilation. It is classified as a Class III medical device under FDA regulations and has received FDA_PMA approval. Available in various sizes (e.g., 035 reference diameter), it is intended for use in controlled clinical settings such as catheterization labs. No MRI safety information is specified in the data.
Other devices from Lutonix
Questions
AI-generated answers, 18 Sep 2026
What types of arteries is the Lutonix Drug Coated Balloon designed to treat, and what are the key size limitations for use?
The Lutonix Drug Coated Balloon is specifically designed for treating de novo (new) or restenotic (recurrent) lesions in **native superficial femoral or popliteal arteries**. It is intended for vessels with reference diameters between **4–6 mm** and lesion lengths up to **150 mm**. The device requires pre-dilation before use, meaning it should only be deployed after an initial balloon angioplasty has prepared the artery.
Is the Lutonix Drug Coated Balloon intended for reuse, or is it a single-use device? How is it supplied?
The Lutonix Drug Coated Balloon is a **single-use, sterile catheter**. It is not designed for reuse, and each catheter is intended for one procedure only. The device is supplied pre-sterilized, ready for immediate use in controlled clinical settings like catheterization labs.
What is the regulatory pathway for this device, and how was its approval determined?
The Lutonix Drug Coated Balloon follows the **FDA Pre-Market Approval (PMA)** pathway, which is required for Class III medical devices. It received **FDA_PMA approval (P130024)** after undergoing a rigorous review process, including an **expedited review** (flagged as expedited). The approval was based on clinical data demonstrating its safety and effectiveness for the specified indications, as outlined in the **advisory committee description (Cardiovascular, CV)**.
Are there specific size variations available for the Lutonix Drug Coated Balloon, and how would a clinician determine the correct size for a patient?
The Lutonix Drug Coated Balloon is available in various sizes, with the **035 reference diameter** being a key model. The correct size is determined by the **reference vessel diameter (4–6 mm)** and lesion length (up to 150 mm). Clinicians should measure the patient’s artery using imaging techniques (e.g., angiography) before selecting the appropriate catheter size to ensure compatibility with the target lesion.
What storage requirements or handling instructions should be followed for the Lutonix Drug Coated Balloon?
While specific storage instructions are not detailed in the provided data, the Lutonix Drug Coated Balloon is supplied as a **sterile, single-use device**. It should be stored in a clean, dry environment, protected from physical damage, and used within its expiration date. Proper handling includes avoiding contamination and ensuring the catheter remains intact until immediate pre-procedure use.