Skip to content

LUTONIX 035 Drug Coated Balloon PTA Catheter, Model 9010

by Lutonix

PMA P170003

Active United States

PMA

Valid until

No expiry

PMA approval is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

PMA P170003↗

FDA record

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA PMA, synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA PMAAPPR Approved NumberP170003 Date25 Aug 2017ApprovedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA PMA Active

Specification

PMA

Full name
LUTONIX® 035 Drug Coated Balloon PTA Catheter
Trade Name
LUTONIX® 035 Drug Coated Balloon PTA Catheter, Model 9010
Generic Name
Drug-coated peripheral transluminal angioplasty catheter
PMA Number
FDA Product Code
PRC
Device Class
Class III
Advisory Committee
Cardiovascular
FDA Decision
APPR Approved

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Lutonix 035 Drug Coated Balloon PTA Catheter is a Drug-Coated Peripheral Transluminal Angioplasty Catheter (as classified by OpenFDA), designed for percutaneous transluminal angioplasty (PTA). It is intended to treat stenotic lesions in dysfunctional native arteriovenous dialysis fistulae, delivering a drug coating to improve vessel dilation and patency in arteries measuring 4 mm to 12 mm in diameter and up to 80 mm in length.

This device is supplied as a single-use, non-sterile catheter and requires pre-dilatation before use. It is approved under FDA_PMA (PMA Number: P170003) and is intended for use in vascular interventional settings. The catheter’s specifications include a 75 cm length, with no additional regulatory or MRI safety restrictions stated in the available data.

Other devices from Lutonix

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What specific types of blood vessels is the Lutonix 035 Drug Coated Balloon PTA Catheter designed to treat, and why is pre-dilatation required before use?

    The Lutonix 035 is designed to treat stenotic lesions in dysfunctional native arteriovenous dialysis fistulae with vessel diameters between 4 mm and 12 mm and lengths up to 80 mm. Pre-dilatation is required because the device is intended for use *after* initial vessel preparation to ensure safe and effective drug-coated balloon dilation, reducing the risk of complications during treatment.

  • Is the Lutonix 035 Drug Coated Balloon PTA Catheter sterile, and how should it be handled before use?

    The Lutonix 035 is supplied as a **non-sterile** catheter, meaning it must be sterilized by the user prior to use in accordance with standard medical sterilization protocols (e.g., ethylene oxide or gamma irradiation) before clinical application. Always follow manufacturer guidelines for sterilization and handling to ensure safety.

  • What are the key dimensions of the Lutonix 035 Drug Coated Balloon PTA Catheter, and how does this affect its clinical use?

    The catheter has a fixed shaft length of **75 cm** and is designed for vessels **4 mm to 12 mm in diameter** and up to **80 mm in lesion length**. These specifications ensure compatibility with common dialysis fistula geometries while allowing flexibility in treating varying stenosis lengths within the approved diameter range.

  • Are there any special storage requirements for the Lutonix 035 Drug Coated Balloon PTA Catheter before use?

    Since the device is non-sterile, it should be stored in a **clean, dry environment** protected from moisture, dust, and extreme temperatures as per standard medical device storage guidelines. After sterilization, follow the manufacturer’s instructions for post-sterilization handling to maintain drug efficacy and device integrity.

  • What regulatory pathway was followed for the Lutonix 035 Drug Coated Balloon PTA Catheter, and what does this mean for clinicians?

    The Lutonix 035 was approved via the **FDA’s PMA (Premarket Approval) process**, which requires rigorous clinical evidence demonstrating safety and effectiveness. This means clinicians can rely on established clinical data supporting its use for PTA in dialysis fistulae, though adherence to the approved indications (e.g., vessel size, pre-dilatation) remains critical for optimal outcomes.