Skip to content

Mammotome EX HH8BEX

by Devicor Medical Products, Inc.

Ref HH8BEX

Mammotome EX HH8BEX is a side-notch biopsy gun handpiece/needle (EU MDD Class IIa; FDA Class II; FDA product code KNW, Instrument, Biopsy) made by Devicor Medical Products, Inc., registered in EUDAMED on 17 Aug 2026 (Basic UDI-DI B-00841911100959), cleared under FDA 510(k) K033700 on 20 Feb 2004 and listed in FDA GUDID since 24 Oct 2016 (UDI-DI 00841911100959), active as of 24 Oct 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

1 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K033700

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00841911100959 Basic UDI-DI 00841911100959UDI-DIDate17 Aug 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00841911100959 UDI-DI Date24 Oct 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK033700 Date20 Feb 2004DecidedStatusActive

Official records

From the FDA record

Device description
Probe and Vacuum Set - CE
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 24 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00841911100959 registered 17 Aug 2026 Active
  • FDA 510(k) K033700 decided 20 Feb 2004 Active
  • FDA GUDID UDI-DI 00841911100959 listed 24 Oct 2016 Listed

Recalls

1 recall · FDA

    • Terminated Z-0440-05 FDA Unclassified (pre-2012) initiated 10 Dec 2004

    A capacitor of the wrong value was used. The capacitor used was 0.11 microfarad instead of 0.22 microfarad called for in the product specifications.

Timeline

4 dated events

  1. Cleared FDA 510(k) K033700
  2. Recall initiated FDA recalls Z-0440-05
  3. Listed FDA GUDID 00841911100959
  4. Registered EUDAMED B-00841911100959

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Mammotome breast biopsy system EUDAMED
Mammotome EX GUDID
Generic name
Side-notch biopsy gun handpiece/needle
Device name
Probe and Vacuum Set
Model / Ref / Catalog
HH8BEX
Primary DI / UDI-DI
00841911100959
Basic UDI-DI
B-00841911100959
510(k) Number
FDA product code
KNW
EMDN code
A019012 Breast nodules and other structures localisation needles and systems
GMDN term
Side-notch biopsy gun handpiece/needle
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
876.1075
EU registration type
Legacy device (under a directive)
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Size
Needle Gauge — 8 Gauge

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under BREAST NODULES AND OTHER STRUCTURES LOCALISATION NEEDLES AND SYSTEMS.

Other devices from Devicor Medical Products, Inc.

See all devices from Devicor Medical Products, Inc. →

Properties

  • Supplied sterile
  • Single use
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (20, all answered No)