microTargeting™ Controller 66-EL-MS-00419
by Fhc, Inc.
microTargeting Controller 66-EL-MS-00419 is a neurological stereotactic surgery system (FDA Class II; FDA product code HAW, Neurological stereotaxic Instrument) made by Fhc, Inc., cleared under FDA 510(k) K011992 on 14 Aug 2001 and listed in FDA GUDID since 17 Sep 2016 (UDI-DI 00873263004197), active as of 22 Oct 2026. 6 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00873263004197 | Date17 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK011992 | Date14 Aug 2001 | StatusActive |
Official records
- AccessGUDID record 00873263004197
- FDA 510(k) database K011992
From the FDA record
- Device description
- microTargeting(TM) Controller
- MRI safety
- MR Unsafe
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K011992 decided 14 Aug 2001 Active
- FDA GUDID UDI-DI 00873263004197 listed 17 Sep 2016 Listed
Recalls
-
- Terminated Z-2353-2018
- Terminated Z-2359-2018
The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.
-
- Terminated Z-0486-2009
Measuring fixture is incorrectly graduated.
-
- Terminated Z-0179-06
- Terminated Z-0180-06
Power Assist microTargeting System may advance beyond intended target
-
- Terminated Z-0895-05
Potential for non-sterile pin to contaminate sterile field
Timeline
- Cleared FDA 510(k) K011992
- Recall initiated FDA recalls Z-0895-05
- Recall initiated FDA recalls Z-0179-06
- Recall initiated FDA recalls Z-0180-06
- Recall initiated FDA recalls Z-0486-2009
- Listed FDA GUDID 00873263004197
- Recall initiated FDA recalls Z-2353-2018
- Recall initiated FDA recalls Z-2359-2018
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- microTargeting™ Controller
- Generic name
- Neurological stereotactic surgery system
- Model / Ref / Catalog
- 66-EL-MS-00419, 66-EL-MS
- Primary DI / UDI-DI
- 00873263004197
- 510(k) Number
- FDA product code
- HAW
- GMDN term
- Neurological stereotactic surgery system
- Device class
- Class II
- Regulation number
- 882.4560
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Unsafe
Similar devices
Other devices filed under FDA product code HAW (Neurological stereotaxic Instrument).
- Cranial Image Guided Surgery System, Navigation Software Cranial, Navigation Software ENT, Registration Software Cranial, Automatic Registration 2.0, Ultrasound Navigation Software (BK), Intraoperative Structure Update by Brainlab AG
- MIDAS REX STEALTH-MIDAS MR8 PM800N by Medtronic Powered Surgical Solutions
- Navitrack System - Total Hip Replacement CT-Free by Orthosoft Inc
- 6000-005-000 by Stryker Leibinger
- NAVIGUS REUSABLE PASSIVE PROBE, MODEL SP-2000 by Image-Guided Neurologics, Inc.
- Leksell Surgiplan, Model 1006947 by Elekta Instrument AB
- Smith & Nephew Image Guided Surgical Instruments for Hip Applications by Smith & Nephew, Inc.
- IPLAN by Brainlab AG
- Instrument Adaptor (6 mm) COIH030D by BRAIN NAVI BIOTECHNOLOGY CO., LTD.
- BRAINLAB STEROTATIC HEADRING by Brainlab Med. Computersysteme GmbH