Skip to content

Microtargeting ™ STar Drive Adapter C0305-00802

by Fhc, Inc.

Microtargeting STar Drive Adapter C0305-00802 is a neurological stereotactic surgery system (FDA Class II; FDA product code HAW, Neurological stereotaxic Instrument) made by Fhc, Inc., cleared under FDA 510(k) K011775 on 30 Aug 2001 and listed in FDA GUDID since 25 Jul 2019 (UDI-DI 00873263008027), active as of 23 Oct 2026. 8 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

510(k) K011775

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00873263008027 UDI-DI Date25 Jul 2019ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK011775 Date30 Aug 2001DecidedStatusActive

Official records

From the FDA record

Device description
STar Adapter for ROSA Surgical Robot
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
Labelled as not made with natural rubber latex
Sterility
Supplied non-sterile; sterilise before use

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K011775 decided 30 Aug 2001 Active
  • FDA GUDID UDI-DI 00873263008027 listed 25 Jul 2019 Listed

Recalls

8 recalls · 1 ongoing · FDA

    • Ongoing Z-0312-2025 FDA Class I initiated 4 Oct 2024

    A complaint was received (MDR 3002250546-2024-00003) prompting an investigation. The investigation revealed a schematic for a spacer tube which is too long relative to the size of other components was included in the build order for Lot 244517 of P/N 66-IT-06P. Use of the product with a spacer tube which is too long could result in intercranial hemorrhaging and brain damage.

  • 6 recalls, same reason

    • Terminated Z-2345-2018 FDA Class II initiated 10 May 2018
    • Terminated Z-2346-2018 FDA Class II initiated 10 May 2018
    • Terminated Z-2347-2018 FDA Class II initiated 10 May 2018
    • Terminated Z-2348-2018 FDA Class II initiated 10 May 2018
    • Terminated Z-2355-2018 FDA Class II initiated 10 May 2018
    • Terminated Z-2356-2018 FDA Class II initiated 10 May 2018

    The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

    • Terminated Z-0895-05 FDA Unclassified (pre-2012) initiated 14 Mar 2005

    Potential for non-sterile pin to contaminate sterile field

Timeline

10 dated events

  1. Cleared FDA 510(k) K011775
  2. Recall initiated FDA recalls Z-0895-05
  3. Recall initiated FDA recalls Z-2345-2018
  4. Recall initiated FDA recalls Z-2346-2018
  5. Recall initiated FDA recalls Z-2347-2018
  6. Recall initiated FDA recalls Z-2348-2018
  7. Recall initiated FDA recalls Z-2355-2018
  8. Recall initiated FDA recalls Z-2356-2018
  9. Listed FDA GUDID 00873263008027
  10. Recall initiated FDA recalls Z-0312-2025

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Microtargeting ™ STar Drive Adapter
Generic name
Neurological stereotactic surgery system
Model / Ref / Catalog
C0305-00802, C0305
Primary DI / UDI-DI
00873263008027
510(k) Number
FDA product code
HAW
GMDN term
Neurological stereotactic surgery system
Device class
Class II
Regulation number
882.4560
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code HAW (Neurological stereotaxic Instrument).

Other devices from Fhc, Inc.

See all devices from Fhc, Inc. →

Properties

  • Sterilise before use
  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (11, all answered No)