Skip to content

microTargeting™ Verfication Probe 66-IT-VP-00371

by Fhc, Inc.

microTargeting Verfication Probe 66-IT-VP-00371 is a neurological stereotactic surgery system (FDA Class II; FDA product code HAW, Neurological stereotaxic Instrument) made by Fhc, Inc., cleared under FDA 510(k) K092562 on 18 Sep 2009 (1 earlier submission) and listed in FDA GUDID since 17 Sep 2016 (UDI-DI 00873263003718), active as of 22 Oct 2026. 15 FDA recalls are linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

15 closed

Documents

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00873263003718 UDI-DI Date17 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Special NumberK092562 Date18 Sep 2009DecidedStatusActive

Official records

From the FDA record

Device description
Target Verification Probe for microTargeting or STar Drive for use with stereotactic frames
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K092562 decided 18 Sep 2009 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00873263003718 listed 17 Sep 2016 Listed

Recalls

15 recalls · FDA

  • 9 recalls, same reason

    • Terminated Z-2349-2018 FDA Class II initiated 10 May 2018
    • Terminated Z-2350-2018 FDA Class II initiated 10 May 2018
    • Terminated Z-2351-2018 FDA Class II initiated 10 May 2018
    • Terminated Z-2352-2018 FDA Class II initiated 10 May 2018
    • Terminated Z-2353-2018 FDA Class II initiated 10 May 2018
    • Terminated Z-2354-2018 FDA Class II initiated 10 May 2018
    • Terminated Z-2357-2018 FDA Class II initiated 10 May 2018
    • Terminated Z-2358-2018 FDA Class II initiated 10 May 2018
    • Terminated Z-2359-2018 FDA Class II initiated 10 May 2018

    The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.

  • 2 recalls, same reason

    • Terminated Z-0312-2011 FDA Unclassified (pre-2012) initiated 30 Mar 2010
    • Terminated Z-0314-2011 FDA Unclassified (pre-2012) initiated 30 Mar 2010

    Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.

    • Terminated Z-0486-2009 FDA Unclassified (pre-2012) initiated 8 Oct 2008

    Measuring fixture is incorrectly graduated.

  • 2 recalls, same reason

    • Terminated Z-0179-06 FDA Unclassified (pre-2012) initiated 31 Oct 2005
    • Terminated Z-0180-06 FDA Unclassified (pre-2012) initiated 31 Oct 2005

    Power Assist microTargeting System may advance beyond intended target

    • Terminated Z-0895-05 FDA Unclassified (pre-2012) initiated 14 Mar 2005

    Potential for non-sterile pin to contaminate sterile field

Timeline

18 dated events

  1. Listed FDA GUDID 00873263003718
  2. Recall initiated FDA recalls Z-2349-2018
  3. Recall initiated FDA recalls Z-2350-2018
  4. Recall initiated FDA recalls Z-2351-2018
  5. Recall initiated FDA recalls Z-2352-2018
  6. Recall initiated FDA recalls Z-2353-2018
  7. Recall initiated FDA recalls Z-2354-2018
  8. Recall initiated FDA recalls Z-2357-2018
  9. Recall initiated FDA recalls Z-2358-2018
  10. Recall initiated FDA recalls Z-2359-2018

8 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
microTargeting™ Verfication Probe
Generic name
Neurological stereotactic surgery system
Model / Ref / Catalog
66-IT-VP-00371, 66-IT-VP
Primary DI / UDI-DI
00873263003718
510(k) Number
FDA product code
HAW
GMDN term
Neurological stereotactic surgery system
Device class
Class II
Regulation number
882.4560
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe
Size
Outer Diameter — 1.83 Millimeter
Length — 262.5 Millimeter

Similar devices

Other devices filed under FDA product code HAW (Neurological stereotaxic Instrument).

Other devices from Fhc, Inc.

See all devices from Fhc, Inc. →

Properties

  • Sterilise before use
  • Prescription use
  • Lot / batch number
  • Manufacturing date
Other properties (11, all answered No)