microTargeting™ Verfication Probe 66-IT-VP-00371
by Fhc, Inc.
microTargeting Verfication Probe 66-IT-VP-00371 is a neurological stereotactic surgery system (FDA Class II; FDA product code HAW, Neurological stereotaxic Instrument) made by Fhc, Inc., cleared under FDA 510(k) K092562 on 18 Sep 2009 (1 earlier submission) and listed in FDA GUDID since 17 Sep 2016 (UDI-DI 00873263003718), active as of 22 Oct 2026. 15 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00873263003718 | Date17 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK092562 | Date18 Sep 2009 | StatusActive |
Official records
- AccessGUDID record 00873263003718
- FDA 510(k) database K092562
- FDA 510(k) database K011992
From the FDA record
- Device description
- Target Verification Probe for microTargeting or STar Drive for use with stereotactic frames
- MRI safety
- MR Unsafe
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use
Across registries
- FDA 510(k) K092562 decided 18 Sep 2009 Active
- FDA GUDID UDI-DI 00873263003718 listed 17 Sep 2016 Listed
Recalls
-
- Terminated Z-2349-2018
- Terminated Z-2350-2018
- Terminated Z-2351-2018
- Terminated Z-2352-2018
- Terminated Z-2353-2018
- Terminated Z-2354-2018
- Terminated Z-2357-2018
- Terminated Z-2358-2018
- Terminated Z-2359-2018
The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.
-
- Terminated Z-0312-2011
- Terminated Z-0314-2011
Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.
-
- Terminated Z-0486-2009
Measuring fixture is incorrectly graduated.
-
- Terminated Z-0179-06
- Terminated Z-0180-06
Power Assist microTargeting System may advance beyond intended target
-
- Terminated Z-0895-05
Potential for non-sterile pin to contaminate sterile field
Timeline
- Listed FDA GUDID 00873263003718
- Recall initiated FDA recalls Z-2349-2018
- Recall initiated FDA recalls Z-2350-2018
- Recall initiated FDA recalls Z-2351-2018
- Recall initiated FDA recalls Z-2352-2018
- Recall initiated FDA recalls Z-2353-2018
- Recall initiated FDA recalls Z-2354-2018
- Recall initiated FDA recalls Z-2357-2018
- Recall initiated FDA recalls Z-2358-2018
- Recall initiated FDA recalls Z-2359-2018
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- microTargeting™ Verfication Probe
- Generic name
- Neurological stereotactic surgery system
- Model / Ref / Catalog
- 66-IT-VP-00371, 66-IT-VP
- Primary DI / UDI-DI
- 00873263003718
- FDA product code
- HAW
- GMDN term
- Neurological stereotactic surgery system
- Device class
- Class II
- Regulation number
- 882.4560
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Unsafe
- Size
- Outer Diameter — 1.83 MillimeterLength — 262.5 Millimeter
Similar devices
Other devices filed under FDA product code HAW (Neurological stereotaxic Instrument).
- VECTORVISION HIP by Brainlab AG
- Disposable Pre-calibrated Brain Biopsy Needle 2.0 by Pajunk GmbH Medizintechnologie
- Zeta Navigation System by ZETA SURGICAL INC.
- 803362 by inomed Medizintechnik GmbH
- WIN-NEUS STEREOTACTIC SURGERY TREATMENT PLANNING SYSTEM by Nuclemed S.A.
- ClearPoint System and Accessories by Mri Interventions, Inc.
- DEPUY CAS KNEE INSTRUMENTATION by DEPUY ORTHOPAEDICS, INC.
- Localite TMS Navigator TS by LOCALITE GmbH
- NAVIGUS II TRAJECTORY GUIDE by Image-Guided Neurologics, Inc.
- LAPDOC I by Robodent GmbH