microTargeting™ Verification Probe 66-IT-VP-03-00845
by Fhc, Inc.
microTargeting Verification Probe 66-IT-VP-03-00845 is a neurological stereotactic surgery system (FDA Class II; FDA product code HAW, Neurological stereotaxic Instrument) made by Fhc, Inc., cleared under FDA 510(k) K092562 on 18 Sep 2009 and listed in FDA GUDID since 28 Oct 2021 (UDI-DI 00873263008454), active as of 23 Oct 2026. 9 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00873263008454 | Date28 Oct 2021 | StatusListed |
| United States | FDA 510(k)SESE | NumberK092562 | Date18 Sep 2009 | StatusActive |
Official records
- AccessGUDID record 00873263008454
- FDA 510(k) database K092562
From the FDA record
- Device description
- 2.0 mm O.D. Verification Probe, 1x for use with microTargeting™ STar™ Drive and microTargeting™ Platform
- MRI safety
- MR Unsafe
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- FDA 510(k) K092562 decided 18 Sep 2009 Active
- FDA GUDID UDI-DI 00873263008454 listed 28 Oct 2021 Listed
Recalls
-
- Terminated Z-2349-2018
- Terminated Z-2350-2018
- Terminated Z-2351-2018
- Terminated Z-2352-2018
- Terminated Z-2354-2018
- Terminated Z-2357-2018
- Terminated Z-2358-2018
The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, and has resulted in the need to remove and replace the implanted lead intraoperative or in a follow-up procedure.
-
- Terminated Z-0312-2011
- Terminated Z-0314-2011
Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead.
Timeline
- Recall initiated FDA recalls Z-0312-2011
- Recall initiated FDA recalls Z-0314-2011
- Recall initiated FDA recalls Z-2349-2018
- Recall initiated FDA recalls Z-2350-2018
- Recall initiated FDA recalls Z-2351-2018
- Recall initiated FDA recalls Z-2352-2018
- Recall initiated FDA recalls Z-2354-2018
- Recall initiated FDA recalls Z-2357-2018
- Recall initiated FDA recalls Z-2358-2018
- Listed FDA GUDID 00873263008454
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- microTargeting™ Verification Probe
- Generic name
- Neurological stereotactic surgery system
- Model / Ref / Catalog
- 66-IT-VP-03-00845, 66-IT-VP-03
- Description
- 2.0 mm O.D. Verification Probe, 1x for use with microTargeting™ STar™ Drive and microTargeting™ Platform
- Primary DI / UDI-DI
- 00873263008454
- 510(k) Number
- FDA product code
- HAW
- GMDN term
- Neurological stereotactic surgery system
- Device class
- Class II
- Regulation number
- 882.4560
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
- MRI safety
- MR Unsafe
Similar devices
Other devices filed under FDA product code HAW (Neurological stereotaxic Instrument).
- Cranial EM System by Brainlab AG
- CI TKR/UKR by Brainlab AG
- StealthStation S8 Platform 9735665 by Medtronic Navigation Inc.
- ORTHOPILOT by Kinamed, Inc.
- GE HEALTHCARE INSTA TRAK 3500PLUS/ FLUORO TRAK 9800 PLUS SYSTEM WITH AXCESS BONE PIN, MODEL PART # 1006955 by GE HealthCare Technologies Inc.
- SNN SCOUT by I.S.G. Technologies, Inc.
- MODIFICATION TO LEKSELL STEREOTACTIC SYSTEM by Elekta Instrument AB
- VIRTUOSO-STEREOTAXIC PLANNING SOFTWARE by Stryker Corp.
- DIEGO POWERED DISSECTOR HANDPIECE WITH STARLINK IMAGE-GUIDED ADAPTER MOUNTING INTERFACE by Gyrus Ent LLC
- AESCULAP ORTHOPILOT 2 THA V 2.0 by AESCULAP, INC.