microTargeting™Array Electrode Insertion Tube Set

FDA UDI

Class II (US FDA UDI)

by Fhc, Inc.

Identity

Trade Name
microTargeting™Array Electrode Insertion Tube Set FDA UDI
Generic Name
Intracerebral cannula, implantable FDA UDI
Device Name
microTargeting Array Electrode Insertion Tube Set, nonsterile, for use with mT Drive. Contains 6 of IT(AR1), 6 of IT(AR2), and 1 of IT(AR3). Individual Specifications: IT(AR1): Electrode Insertion Tube - 239.9mm, OD=0.88mm, ID=0.58mm. IT(AR2): Lower Guide Spacer - OD=1.83mm, ID=0.97mm (does not enter brain). IT(AR3): Lead Insertion Tube - 239.9mm, OD=1.83mm, ID=1.60mm. Also contains one 66-AC-AR Array Electrode Carrier and one 66-CN-ET Electrode Extraction Tool. FDA UDI
Model / Reference
FC1012-00153 FDA UDI
Description
microTargeting Array Electrode Insertion Tube Set, nonsterile, for use with mT Drive. Contains 6 of IT(AR1), 6 of IT(AR2), and 1 of IT(AR3). Individual Specifications: IT(AR1): Electrode Insertion Tube - 239.9mm, OD=0.88mm, ID=0.58mm. IT(AR2): Lower Guide Spacer - OD=1.83mm, ID=0.97mm (does not enter brain). IT(AR3): Lead Insertion Tube - 239.9mm, OD=1.83mm, ID=1.60mm. Also contains one 66-AC-AR Array Electrode Carrier and one 66-CN-ET Electrode Extraction Tool. FDA UDI

Identifiers

Catalog Number
FC1012 FDA UDI
Primary DI / UDI-DI
00873263001530 FDA UDI
510(k) Number
K011775 FDA UDI
FDA Product Code
HAW FDA UDI
GMDN Term
Intracerebral cannula, implantable FDA UDI

Classification

Device Class
Class II FDA UDI
Regulation Number
882.4560 FDA UDI
Commercial Distribution
Not in Commercial Distribution FDA UDI

Clinical & Handling

Sterile

No

FDA UDI

Single Use

No

FDA UDI

Implantable

Yes

FDA UDI

Contains Latex

No

FDA UDI

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

Yes

FDA UDI

Serial Number

No

FDA UDI

Expiration Date

Yes

FDA UDI

Manufacturing Date

No

FDA UDI
MRI Safety
MR Unsafe FDA UDI

microTargeting™Array Electrode Insertion Tube Set by Fhc, Inc. — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS

Cleared under the same submission

Authorization Coverage (1 country)

Regulatory Authorizations

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Manufacturer
Fhc, Inc.

Sources (1)

  • FDA UDI c7dd5cd3-cd7c-4d5e-8c9a-83f6620b03d8 38 fields · synced May 30, 2026