Skip to content

MiniMed Flex Charger 8XX

by Medtronic MINIMED

Ref MMT-8070

MiniMed Flex Charger 8XX (MMT-8070) is a noninvasive device battery charger (EU MDR Class I; FDA Class II; FDA product code QFG, Alternate controller enabled insulin infusion pump) made by Medtronic Minimed, Inc., registered in EUDAMED on 14 Sep 2026 (Basic UDI-DI 0763000B00032137N), cleared under FDA 510(k) K253743 on 12 Mar 2026 and listed in FDA GUDID since 24 May 2026 (UDI-DI 00199150021031), active as of 23 Oct 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K253743

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0763000B00032137N Basic UDI-DI 00199150021031UDI-DIDate14 Sep 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00199150021031 UDI-DI Date24 May 2026ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK253743 Date12 Mar 2026DecidedStatusActive

Official records

From the FDA record

Device description
HARGER MMT-8070 8XX FLEX REPL
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0763000B00032137N registered 14 Sep 2026 Active
  • FDA 510(k) K253743 decided 12 Mar 2026 Active
  • FDA GUDID UDI-DI 00199150021031 listed 24 May 2026 Listed

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-0088-2027 FDA Class II initiated 20 Aug 2026

    Some MiniMed Flex insulin pumps were released with missing (i.e., devices with no result or abort test results are presumed to have failed) or failed verification test results in one or more of 9 functional tests. The unverified/failed pumps released to users potentially have one or more of the following issues: inoperable pump at setup, lack of protection for moisture exposure, slow battery charging, disconnection issues with other system components (i.e., continuous glucose monitoring sensor or MiniMed mobile app), reduced ability to detect occlusion events, compromised audio for pump alarms/alerts, and/or inaccurate insulin delivery.

Timeline

4 dated events

  1. Cleared FDA 510(k) K253743
  2. Listed FDA GUDID 00199150021031
  3. Recall initiated FDA recalls Z-0088-2027
  4. Registered EUDAMED 0763000B00032137N

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
MiniMed Flex
Generic name
Noninvasive device battery charger
Device name
MiniMed Flex Charger 8XX
Model / reference
MMT-8070
Primary DI / UDI-DI
00199150021031
Basic UDI-DI
0763000B00032137N
510(k) Number
FDA product code
QFG
EMDN code
Z1204021680 Portable microinfusion instruments - hardware accessories
GMDN term
Noninvasive device battery charger
Device class
Class I EUDAMED
Class II GUDID
Regulation number
880.5730
EU registration type
Standard device
EU market of registration
Austria
GUDID distribution status
In Commercial Distribution
MRI safety
MR Unsafe

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
US-MF-000023100
Authorised representative
Medtronic B.V. NL-AR-000006050

Similar devices in this category

Other devices filed under PORTABLE MICROINFUSION INSTRUMENTS.

Other devices from Medtronic Minimed, Inc.

See all devices from Medtronic Minimed, Inc. →

Properties

  • Prescription use
  • Convenience kit
  • Lot / batch number