Identity
- Trade Name
- mintLesion™ FDA UDI
- Generic Name
- Radiology DICOM image processing application software FDA UDI
- Device Name
- mint Lesion EUDAMEDThe product mint Lesion helps qualified radiologists with the image-based diagnosis and treatment response assessment of oncological diseases. Fields of application are radiological diagnosis and follow-up examinations in oncology, as well as clinical or pharmaceutical drug trials across a defined group of patients. mint Lesion implements various radiological guidelines and response evaluation criteria, such as RECIST (Response Evaluation Criteria In Solid Tumors). This also includes the assessment of the stage of oncological disease (staging) and the objective response to therapy (e.g. timepoint response / overall response). The timepoint response is an empirical measure to evaluate therapy success according to the response criteria in use. It is mainly used to assess patient cohorts in the course of clinical trials of novel therapy agents. The timepoint response may differ from a radiological assessment of response to therapy and must not be used as a surrogate. mint Lesion allows for the documentation of size and assessment of changes in size of solid tumors described by the respective criteria that are monitored by means of radiological imaging (computed tomography (CT), magnetic resonance imaging (MRI), nuclear medicine (PET, NM), digital radiography (XR, CR)). mint Lesion follows the typical workflow of follow-up examinations, from assessment to reporting, and enables the integration of a clinical-radiological software environment (PACS, Picture Archiving and Communication System). Assessment results can be exported into different electronical formats and processed further by other applications. FDA UDI
- Model / Reference
- mint Lesion 3.10 EUDAMED3.10.0 FDA UDI
- Description
- The product mint Lesion helps qualified radiologists with the image-based diagnosis and treatment response assessment of oncological diseases. Fields of application are radiological diagnosis and follow-up examinations in oncology, as well as clinical or pharmaceutical drug trials across a defined group of patients. mint Lesion implements various radiological guidelines and response evaluation criteria, such as RECIST (Response Evaluation Criteria In Solid Tumors). This also includes the assessment of the stage of oncological disease (staging) and the objective response to therapy (e.g. timepoint response / overall response). The timepoint response is an empirical measure to evaluate therapy success according to the response criteria in use. It is mainly used to assess patient cohorts in the course of clinical trials of novel therapy agents. The timepoint response may differ from a radiological assessment of response to therapy and must not be used as a surrogate. mint Lesion allows for the documentation of size and assessment of changes in size of solid tumors described by the respective criteria that are monitored by means of radiological imaging (computed tomography (CT), magnetic resonance imaging (MRI), nuclear medicine (PET, NM), digital radiography (XR, CR)). mint Lesion follows the typical workflow of follow-up examinations, from assessment to reporting, and enables the integration of a clinical-radiological software environment (PACS, Picture Archiving and Communication System). Assessment results can be exported into different electronical formats and processed further by other applications. FDA UDI
Identifiers
- Primary DI / UDI-DI
- 04260495883106 EUDAMEDFDA UDI
- Basic UDI-DI
- 426049588MINTLESIONSM EUDAMED
- Direct Marketing DI
- 04260495883106 EUDAMED
- 510(k) Number
- K142647 FDA UDI
- FDA Product Code
- LLZ FDA UDI
- EMDN Code
- Z11030582 RADIOLOGY INSTRUMENTS - SOFTWARE ACCESSORIES EUDAMED
- GMDN Term
- Radiology DICOM image processing application software FDA UDI
Classification
- Device Class
- Class IIb EUDAMEDClass II FDA UDI
- Regulation Number
- 892.2050 FDA UDI
- Special Device Type
- Software EUDAMED
- Market of Registration
- Germany EUDAMED
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
No
EUDAMEDFDA UDI
Single Use
No
FDA UDI
Implantable
No
EUDAMEDFDA UDI
Reusable
No
EUDAMED
Contains Latex
No
EUDAMEDFDA UDI
Reprocessed
No
EUDAMED
CMR Substance
No
EUDAMED
Human-derived
No
EUDAMED
Human Tissues
No
EUDAMED
Animal Tissues
No
EUDAMED
Endocrine Disruptor
No
EUDAMED
Administering Medicine
No
EUDAMED
Measuring Function
Yes
EUDAMED
Incorporates Medicinal Product
No
EUDAMED
Prescription Use
No
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
Yes
FDA UDI
Serial Number
No
FDA UDI
Expiration Date
No
FDA UDI
Manufacturing Date
Yes
FDA UDI
mint Lesion by Mint Medical GmbH — Class IIb — MDR, FDA UDI — listed in EUDAMED, FDA GUDID — regulatory data on deviCERTS
Authorization Coverage (2 countries)
Regulatory Authorizations
European Union Active
CE/MDR
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| EUDAMED | European Union | CE/MDR | 426049588MINTLESIONSM | Class IIb | Active |
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class IIb | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Mint Medical GmbH
- EUDAMED SRN
- DE-MF-000020202
Sources (2)
- EUDAMED 033f6757-0539-47e5-8ce9-aa250517b8e2 61 fields · synced Jul 15, 2026
- FDA UDI 5af24825-06e5-437e-86b3-6cc781d19765 34 fields · synced May 25, 2026