mint Lesion
by Mint Medical GmbH 4 variants
Ref mint Lesion 3.9
mint Lesion 3.9 is a medical device (EU MDR Class IIb; FDA Class II; FDA product code LLZ, System, Image Processing, Radiological; EMDN category radiology instruments - software accessories) made by Mint Medical GmbH, registered in EUDAMED on 18 Jul 2022 (Basic UDI-DI 426049588MINTLESIONSM), cleared under FDA 510(k) K142647 on 13 Apr 2015 and listed in FDA GUDID since 8 Mar 2023 (UDI-DI 04260495880396), active as of 22 Oct 2026. 3 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
3 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing GUDID | Number04260495880396 | Date8 Mar 2023 | StatusListed |
| European Union | CE/MDR EUDAMED | Number426049588MINTLESIONSM 04260495880396 | Date18 Jul 2022 | StatusActive |
| United States | FDA 510(k) GUDID | NumberK142647 | Date13 Apr 2015 | StatusActive |
Official records
- EUDAMED public site 426049588MINTLESIONSM
- AccessGUDID record 04260495880396
- FDA 510(k) database K142647
From the FDA record
- Device description
- The product mint Lesion helps qualified radiologists with the image-based diagnosis and treatment response assessment of oncological diseases. Fields of application are radiological diagnosis and follow-up examinations in oncology, as well as clinical or pharmaceutical drug trials across a defined group of patients. mint Lesion implements various radiological guidelines and response evaluation criteria, such as RECIST (Response Evaluation Criteria In Solid Tumors). This also includes the assessment of the stage of oncological disease (staging) and the objective response to therapy (e.g. timepoint response / overall response). The timepoint response is an empirical measure to evaluate therapy success according to the response criteria in use. It is mainly used to assess patient cohorts in the course of clinical trials of novel therapy agents. The timepoint response may differ from a radiological assessment of response to therapy and must not be used as a surrogate. mint Lesion allows for the documentation of size and assessment of changes in size of solid tumors described by the respective criteria that are monitored by means of radiological imaging (computed tomography (CT), magnetic resonance imaging (MRI), nuclear medicine (PET, NM), digital radiography (XR, CR)). mint Lesion follows the typical workflow of follow-up examinations, from assessment to reporting, and enables the integration of a clinical-radiological software environment (PACS, Picture Archiving and Communication System). Assessment results can be exported into different electronical formats and processed further by other applications.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 426049588MINTLESIONSM registered 18 Jul 2022 Active
- FDA 510(k) K142647 decided 13 Apr 2015 Active
- FDA GUDID UDI-DI 04260495880396 listed 8 Mar 2023 Listed
Recalls
-
- Ongoing Z-2068-2026
If the connection between a mint Lesion workstation and the mint Lesion server is interrupted while performing a read, in rare cases some information may be lost or incorrectly linked to other patients.
-
- Ongoing Z-0709-2025
- Ongoing Z-0710-2025
Some software versions have a malfunction where they may show incorrect orientation labels for a specific subset of DICOM images.
Timeline
- Cleared FDA 510(k) K142647
- Registered EUDAMED 426049588MINTLESIONSM
- Listed FDA GUDID 04260495880396
- Recall initiated FDA recalls Z-0709-2025
- Recall initiated FDA recalls Z-0710-2025
- Recall initiated FDA recalls Z-2068-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- mintLesion™
- Generic name
- Radiology DICOM image processing application software
- Model / reference
- mint Lesion 3.9 EUDAMED3.9.0 GUDID
- Primary DI / UDI-DI
- 04260495880396
- Basic UDI-DI
- 426049588MINTLESIONSM
- Direct marketing DI
- 04260495880396
- 510(k) Number
- FDA product code
- LLZ
- EMDN code
- Z11030582 Radiology instruments - software accessories
- GMDN term
- Radiology DICOM image processing application software
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 892.2050
- Special device type
- Software
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | mint Lesion 3.9 | 3.9.0 |
| Device class | Class IIb | Class II |
Manufacturer details
- EUDAMED SRN
- DE-MF-000020202
Similar devices in this category
Other devices filed under RADIOLOGY INSTRUMENTS - SOFTWARE ACCESSORIES.
- SubtleMR (Software as a Service for post-processing of Magnetic Resonance data) 2.x by Subtle Medical, Inc.
- cvi42 v6.X by Circle Cardiovascular Imaging
- Annalise Enterprise AnnaliseENTP4 by HARRISON-AI MEDICAL PTY LTD
- Tempus Pixel AMM7 by Arterys Inc.
- QyScore by QYNAPSE
- OmegaAI Image Viewer OAIIV1 by Ramsoft Inc
- SpineQ SpineQ v2.0.1 by Bonescreen GmbH
- SubtleHD 1.x by Subtle Medical, Inc.
- Annalise Enterprise AnnaliseENTP5 by HARRISON-AI MEDICAL PTY LTD
- SpineQ SpineQ v1.3.0 by Bonescreen GmbH