MP Reconstruction Prosthesis 172-930/22
by WALDEMAR LINK GmbH & Co. KG
Part of a family of 40 devices: see the family page
Ref 172-930/22Model Hip stem, uncemented, Ti6Al4V, ribbed
MP Reconstruction Prosthesis 172-930/22 is a device of GMDN type press-fit hip femur prosthesis (EU MDR Class III; FDA Class II) made by WALDEMAR LINK GmbH & Co. KG, registered in EUDAMED on 27 May 2026 (Basic UDI-DI 4026575-1-HSR-050001-Y3) with CE/MDR certificate 13792GB450240723 valid until 22 Jul 2029, cleared under FDA 510(k) K142187 on 6 Nov 2014 and listed in FDA GUDID since 1 Nov 2015 (UDI-DI 04026575203000), active as of 25 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
22 Jul 2029
FDA recalls
1 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number4026575-1-HSR-050001-Y3 04026575203000 | Date27 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04026575203000 | Date1 Nov 2015 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK142187 | Date6 Nov 2014 | StatusActive |
Official records
- EUDAMED public site 4026575-1-HSR-050001-Y3
- AccessGUDID record 04026575203000
- FDA 510(k) database K142187
From the FDA record
- Device description
- Hip Prosthesis Stem,Size 11
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI 4026575-1-HSR-050001-Y3 registered 27 May 2026 Active
- FDA 510(k) K142187 decided 6 Nov 2014 Active
- FDA GUDID UDI-DI 04026575203000 listed 1 Nov 2015 Listed
Certificates
- 13792GB450240723 Active
Technical documentation EU MDR
- Certifier
- DNV MEDCERT GmbH 0482
- Issued
- 23 Jul 2024
- Expires
- 22 Jul 2029
Recalls
-
- Ongoing Z-0769-2025
Error on the main label and the patient label. The labels indicate a size XXL, this is a standard-size neck segment.. All further information on the labels is correct (Length, CCD and Offset).
-
- Terminated Z-0733-2019
The reaming guide and the guide rod can't be screwed into the intended depth. The reason for this is a reduced depth of the core hole in the stem. A reaming guide that is not screwed in completely may lead to a proximal preparation in the depth that is not sufficient and to a neck that can't be positioned correctly. The correct fit of the neck can't be verified by means of the guide rod.
Timeline
- Cleared FDA 510(k) K142187
- Listed FDA GUDID 04026575203000
- Recall initiated FDA recalls Z-0733-2019
- Certificate issued EUDAMED 13792GB450240723
- Recall initiated FDA recalls Z-0769-2025
- Registered EUDAMED 4026575-1-HSR-050001-Y3
- Certificate expires EUDAMED 13792GB450240723
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- MP Reconstruction Prosthesis
- Generic name
- Press-fit hip femur prosthesis, modular
- Device name
- MP Reconstruction System
- Model / Ref / Catalog
- 172-930/22, Hip stem, uncemented, Ti6Al4V, ribbed
- Primary DI / UDI-DI
- 04026575203000
- Basic UDI-DI
- 4026575-1-HSR-050001-Y3
- 510(k) Number
- FDA product code
- LZO, LWJ, JDI
- EMDN code
- P090804010206 Uncemented femoral stems for primary implant, with modular neck, straight
- GMDN term
- Press-fit hip femur prosthesis, modular
- Device class
- Class III EUDAMEDClass II GUDID
- Regulation number
- 888.3353, 888.3360, 888.3350
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class III | Class II |
Similar devices in this category
Other devices filed under PRIMARY IMPLANT UNCEMENTED FEMORAL STEMS.
- M-Vizion Femoral Revision System 01.22.534 by Medacta International SA
- M-Vizion Femoral Revision System 01.22.574 by Medacta International SA
- 65-7711-022-20 by Zimmer, Inc.
- Furlong® H-A.C. Cementless Femoral Stem 140° CCD Angle - Standard Offset 14mm 81-14-12 by JRI Orthopaedics Ltd
- 65-7711-007-20 by Zimmer, Inc.
- Wedge-shaped Stem F13AB-PA00639 by WUHAN MINDRAY SCIENTIFIC CO., LTD.
- A2® short stem 311108 by ARTIQO GmbH
- Conformity stem, high offset, collared, #11 1110-1211 by UNITED ORTHOPEDIC CORP.
- TST Calcar Replacement Hip Prosthesis System 10932561216 by TST RAKOR VE TIBBİ ALETLER SAN.VE TİC.LTD.ŞTİ.
- MIS Cementless Femoral Stem T26510004S by Tianjin Zhengtian Medical Instrument Co., Ltd.